非球形指数与尺寸比在93例纵向研究中识别生长性与稳定性动脉瘤的形态学差异
本研究从医疗中心选取2015年有随访影像的93例颅内未破裂动脉瘤(23例生长,70例稳定),基于348次3D成像重建动脉瘤几何形态并计算形态学特征。结果显示,在相似大小的动脉瘤中,生长性与稳定性动脉瘤的形态学特征存在差异,非球形指数在生长性动脉瘤中更高,且基于初始影像鉴别生长与稳定的非球形指数ROC曲线下面积为0.721;尺寸比是第二显著的相关参数。
要点
- 在相似大小的未破裂颅内动脉瘤中,生长性与稳定性动脉瘤的形态学特征存在差异。
- 生长性动脉瘤的非球形指数更高,基于初始影像鉴别生长与稳定的ROC曲线下面积为0.721。
- 尺寸比是第二显著与生长相关的参数。
核心结论
- 在相似大小的动脉瘤中,生长性与稳定性动脉瘤的形态学特征似乎存在差异;非球形指数在生长性动脉瘤中更高,尺寸比是第二显著与生长相关的参数。
研究设计与样本
- 从医疗中心选取2015年有随访影像日期的93例颅内动脉瘤(23例生长,70例稳定),收集所有CTA诊断与随访图像共348次3D成像研究,重建动脉瘤3D几何形态并计算体积、表面积、非球形指数、纵横比和尺寸比。
诊断标准与关键数值
- 对于<3 mm动脉瘤,非球形指数P < .001;3-5 mm,非球形指数P < .001;5-7 mm,尺寸比P = .003;>7 mm,体积P < .001、表面积P < .001、非球形指数P = .002。
- 前交通动脉中非球形指数P = .008;后交通动脉中尺寸比P = .004。
- 基于初始影像鉴别生长与稳定病例的非球形指数ROC曲线下面积为0.721。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Recent studies have strongly associated intracranial aneurysm growth with increased risk of rupture. Identifying aneurysms that are likely to grow would be beneficial to plan more effective monitoring and intervention strategies. Our hypothesis is that for unruptured intracranial aneurysms of similar size, morphologic characteristics differ between aneurysms that continue to grow and those that do not.
MATERIALS AND METHODS: From aneurysms in our medical center with follow-up imaging dates in 2015, ninety-three intracranial aneurysms (23 growing, 70 stable) were selected. All CTA images for the aneurysm diagnosis and follow-up were collected, a total of 348 3D imaging studies. Aneurysm 3D geometry for each imaging study was reconstructed, and morphologic characteristics, including volume, surface area, nonsphericity index, aspect ratio, and size ratio were calculated.
RESULTS: Morphologic characteristics were found to differ between growing and stable groups. For aneurysms of <3 mm, nonsphericity index (P < .001); 3-5 mm, nonsphericity index (P < .001); 5-7 mm, size ratio (P = .003); >7 mm, volume (P < .001); surface area (P < .001); and nonsphericity index (P = .002) were significant. Within the anterior communicating artery, the nonsphericity index (P = .008) and, within the posterior communicating artery, size ratio (P = .004) were significant. The nonsphericity index receiver operating characteristic area under the curve was 0.721 for discriminating growing and stable cases on the basis of initial images.
CONCLUSIONS: Among aneurysms with similar sizes, morphologic characteristics appear to differ between those that are growing and those that are stable. The nonsphericity index, in particular, was found to be higher among growing aneurysms. The size ratio was found to be the second most significant parameter associated with growth.
引用
- Chien A, Xu M, Yokota H, et al. Nonsphericity Index and Size Ratio Identify Morphologic Differences between Growing and Stable Aneurysms in a Longitudinal Study of 93 Cases. AJNR Am J Neuroradiol. 2018. PMID: 29371255. doi:10.3174/ajnr.A5531