多参数分析渗透性与ADC直方图指标用于按肿瘤分级对儿童脑肿瘤进行分类
回顾性纳入41例新诊断强化脑肿瘤患儿(低级别16例,高级别25例),行DTI及动态对比增强MR成像,计算渗透性指标和ADC直方图指标。高级别肿瘤的转运常数和速率常数更高、细胞外血管外容积分数更低(P < .001),FLAIR和强化肿瘤体积的平均ADC显著更低(P < .001)。细胞外容积分数联合FLAIR体积平均ADC鉴别高低级别肿瘤的AUC为0.918。
要点
- 高级别儿童脑肿瘤的转运常数和速率常数更高,细胞外血管外容积分数更低(P < .001)。
- 高级别肿瘤FLAIR和强化肿瘤体积的平均ADC显著低于低级别肿瘤(P < .001)。
- 细胞外容积分数联合FLAIR体积平均ADC鉴别高低级别肿瘤的AUC为0.918。
核心结论
- ADC直方图指标联合渗透性指标能以高准确度鉴别低级别与高级别儿童脑肿瘤。
研究设计与样本
- 经机构审查委员会批准的回顾性分析,纳入41例新诊断强化脑肿瘤患儿(年龄0.3-16.76岁,平均6.22岁;低级别16例,高级别25例)。
诊断标准与关键数值
- 高级别肿瘤的转运常数(从血浆进入细胞外血管外间隙)和速率常数(从细胞外血管外间隙返回血浆)更高,细胞外血管外容积分数更低(P < .001)。
- 高级别肿瘤FLAIR体积和强化肿瘤体积的平均ADC显著更低(P < .001)。
- 细胞外血管外容积分数联合FLAIR体积平均ADC鉴别高低级别肿瘤的AUC为0.918。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Accurate tumor grading is essential for treatment planning of pediatric brain tumors. We hypothesized that multiparametric analyses of a combination of permeability metrics and ADC histogram metrics would differentiate high- and low-grade tumors with high accuracy.
MATERIALS AND METHODS: DTI and dynamic contrast-enhanced MR imaging using T1-mapping with flip angles of 2°, 5°, 10°, and 15°, followed by a 0.1-mmol/kg body weight gadolinium-based bolus was performed on all patients in addition to standard MR imaging. Permeability data were processed and transfer constant from the blood plasma into the extracellular extravascular space, rate constant from the extracellular extravascular space back into blood plasma, extravascular extracellular volume fraction, and fractional blood plasma volume were calculated from 3D tumor volumes. Apparent diffusion coefficient histogram metrics were calculated for 3 separate tumor volumes derived from T2-FLAIR sequences, T1 contrast-enhanced sequences, and permeability maps, respectively.
RESULTS: Results from 41 patients (0.3-16.76 years of age; mean, 6.22 years) with newly diagnosed contrast-enhancing brain tumors (16 low-grade; 25 high-grade) were included in the institutional review board-approved retrospective analysis. Wilcoxon tests showed a higher transfer constant from blood plasma into extracellular extravascular space and rate constant from extracellular extravascular space back into blood plasma, and lower extracellular extravascular volume fraction (P < .001) in high-grade tumors. The mean ADCs of FLAIR and enhancing tumor volumes were significantly lower in high-grade tumors (P < .001). ROC analysis showed that a combination of extravascular volume fraction and mean ADC of FLAIR volume differentiated high- and low-grade tumors with high accuracy (area under receiver operating characteristic curve = 0.918).
CONCLUSIONS: ADC histogram metrics combined with permeability metrics differentiate low- and high-grade pediatric brain tumors with high accuracy.
引用
- Vajapeyam S, Brown D, Johnston PR, et al. Multiparametric Analysis of Permeability and ADC Histogram Metrics for Classification of Pediatric Brain Tumors by Tumor Grade. AJNR Am J Neuroradiol. 2018. PMID: 29301780. doi:10.3174/ajnr.A5502