双能颈动脉及颅内CT血管造影中虚拟单能成像算法的评估:对图像质量、伪影及狭窄检出诊断性能的影响
这项回顾性研究纳入40例患者的三代192层双源CT双能头颈CTA,比较线性融合、VMI与VMI+算法的图像质量、伪影及狭窄评估。40-keV VMI+的CNR最高,VMI与VMI+在颅内及颈内动脉评估适用性优于线性融合,狭窄检出与分级一致性极好且诊断性能无差异。
要点
- 40-keV VMI+的CNR高于65-keV VMI和线性融合图像(P<0.001)。
- VMI与VMI+在颅内及颈内动脉评估的适用性显著高于线性融合(P<0.002)。
- VMI与VMI+对颈动脉分叉及虹吸段狭窄的检出与分级一致性极好,诊断性能无差异。
核心结论
- 在头颈双能CTA中,40-keV VMI+较65-keV VMI和线性融合序列定量图像质量更优;VMI与VMI+提高了颈动脉和颅内动脉评估适用性且狭窄评估极好,但未转化为诊断性能的提高。
研究设计与样本
- 回顾性研究,纳入40例患者,使用第三代192层双源CT扫描仪行双能CTA,重建120-kVp等效线性融合、VMI及VMI+序列。
关键影像表现/征象
- 定量分析评估主动脉、颈总动脉、颈内动脉、大脑中动脉及基底动脉的对比噪声比(CNR)。
- 40-keV VMI+的CNR最高,高于65-keV VMI和线性融合图像(P<0.001)。
- 所有定性评估序列伪影均较低,在肩部及分叉高度对主动脉上动脉评估适用性极好。
- 颅内及颈内动脉评估适用性VMI+和VMI显著高于线性融合图像(P<0.002)。
诊断标准与关键数值
- 三位放射科医师采用5点Likert量表评估肩部高度、颈动脉分叉、虹吸段及颅内水平的伪影和评估适用性。
- 在颈动脉分叉和虹吸段进行狭窄检出与分级。
- VMI与VMI+对颈动脉分叉和虹吸段狭窄的检出与分级一致性极好,诊断性能无差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the impact of traditional (VMI) and noise-optimized virtual monoenergetic imaging (VMI+) algorithms on quantitative and qualitative image quality, and the assessment of stenosis in carotid and intracranial dual-energy CTA (DE-CTA).
MATERIALS AND METHODS: DE-CTA studies of 40 patients performed on a third-generation 192-slice dual-source CT scanner were included in this retrospective study. 120-kVp image-equivalent linearly-blended, VMI and VMI+ series were reconstructed. Quantitative analysis included evaluation of contrast-to-noise ratios (CNR) of the aorta, common carotid artery, internal carotid artery, middle cerebral artery, and basilar artery. VMI and VMI+ with highest CNR, and linearly-blended series were rated qualitatively. Three radiologists assessed artefacts and suitability for evaluation at shoulder height, carotid bifurcation, siphon, and intracranial using 5-point Likert scales. Detection and grading of stenosis were performed at carotid bifurcation and siphon.
RESULTS: Highest CNR values were observed for 40-keV VMI+ compared to 65-keV VMI and linearly-blended images (P < 0.001). Artefacts were low in all qualitatively assessed series with excellent suitability for supraaortic artery evaluation at shoulder and bifurcation height. Suitability was significantly higher in VMI+ and VMI compared to linearly-blended images for intracranial and ICA assessment (P < 0.002). VMI and VMI+ showed excellent accordance for detection and grading of stenosis at carotid bifurcation and siphon with no differences in diagnostic performance.
CONCLUSION: 40-keV VMI+ showed improved quantitative image quality compared to 65-keV VMI and linearly-blended series in supraaortic DE-CTA. VMI and VMI+ provided increased suitability for carotid and intracranial artery evaluation with excellent assessment of stenosis, but did not translate into increased diagnostic performance.
引用
- Leithner D, Mahmoudi S, Wichmann JL, et al. Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: Effects on image quality, artefacts and diagnostic performance for the detection of stenosis. Eur J Radiol. 2017. PMID: 29362140. doi:10.1016/j.ejrad.2017.12.024