低管电压CT联合减量对比剂用于右侧肾上腺静脉成像的图像质量与辐射剂量
120例肾上腺CT患者随机分为三组:120kV联合600mgI/kg对比剂组、80kV联合600mgI/kg组、80kV联合360mgI/kg组。三组右侧肾上腺静脉检出率及可视化评分无显著差异,80kV联合360mgI/kg组与常规组CNR、SNR无显著差异,且SSDE较常规组显著降低(5.86mGy±1.44 vs 7.27mGy±1.81,P<0.001)。
要点
- 80kV联合360mgI/kg对比剂方案右侧肾上腺静脉检出率为97.3%,与常规120kV联合600mgI/kg方案(95%)无显著差异。
- 80kV联合360mgI/kg组SSDE为5.86mGy±1.44,显著低于常规组7.27mGy±1.81(P<0.001),降幅19%。
- 80kV联合360mgI/kg组与常规组CNR、SNR无显著差异,三组可视化评分无显著差异(P=0.152)。
核心结论
- 80kV扫描联合360mgI/kg对比剂用于右侧肾上腺静脉成像,检出率与常规扫描相当,同时SSDE降低19%。
研究设计与样本
- 随机对照研究,120例接受肾上腺CT的患者随机分为三组:600-120组(600mgI/kg对比剂、120kV)、600-80组(600mgI/kg对比剂、80kV)、360-80组(360mgI/kg对比剂、80kV),80kV组采用迭代重建。
诊断标准与关键数值
- 右侧肾上腺静脉检出率:600-120组95%、600-80组97.2%、360-80组97.3%(P=1.000);可视化评分三组间无显著差异(P=0.152);600-120组与360-80组CNR、SNR无显著差异;SSDE:360-80组5.86mGy±1.44 vs 600-120组7.27mGy±1.81(P<0.001)。
临床应用与阅片要点
- 采用80kV联合360mgI/kg对比剂方案行右侧肾上腺静脉CT成像,可在维持检出率与图像质量的同时降低辐射剂量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare image quality and radiation dose of right adrenal vein (RAV) imaging computed tomography (CT) among conventional, low kV, and low kV with reduced contrast medium protocols.
METHODS: One-hundred-and-twenty patients undergoing adrenal CT were randomly assigned to one of three protocols: contrast dose of 600mgI/kg at 120-kV tube voltage setting (600-120 group), 600mgI/kg at 80kV (600-80 group), and 360mgI/kg at 80kV (360-80 group). Iterative reconstruction was used for 80-kV groups. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the RAV and size-specific dose estimates (SSDE) were measured. Three radiologists evaluated 4-point visualisation scores of RAV by consensus reading.
RESULTS: The RAV detectability was 95%, 97.2%, and 97.3% for 600-120, 600-80, and 360-80 groups, respectively (p=1.000). Visualisation scores were not significantly different among the groups (p=0.152). There were no significant differences in CNR or SNR between the 600-120 and 360-80 groups. SSDE of the 360-80 group was significantly lower than that of the 600-120 group (5.86mGy±1.44 vs. 7.27mGy±1.81, p<0.001).
CONCLUSIONS: 80-kV scans with 360 mgI/kg contrast media showed comparable detectability of RAV to conventional scans, while reducing 19% of SSDE.