文献速递腹部CT

标准剂量与低辐射剂量CT小肠造影对克罗恩病定量评估的前瞻性比较

Prospective Comparison of Standard- Versus Low-Radiation-Dose CT Enterography for the Quantitative Assessment of Crohn Disease.
PubMed 文献 · AJR Am J Roentgenol · 2017-12-20

163例因克罗恩病评估行CT小肠造影的患者同日随机顺序接受标准剂量检查(滤过反投影与自适应统计迭代重建ASIR图像)和低剂量基于模型的迭代重建(MBIR)CTE,以ASIR影像和临床疾病活动度评估为参考标准,MBIR与两种标准剂量技术非劣效,低剂量扫描敏感度0.85~0.94、特异度0.84~0.97(取决于阅片者),MBIR平均辐射暴露较标准剂量降低3.30±3.17 mSv(标准剂量7.16±4.61 mSv,p<0.001)。

要点

  • 低剂量MBIR CTE对克罗恩病活动性炎症的敏感度0.85~0.94、特异度0.84~0.97(以ASIR为参考标准,取决于阅片者)。
  • MBIR与标准剂量滤过反投影及ASIR图像相比,与临床参考标准比较无显著差异。
  • MBIR平均辐射暴露较标准剂量降低3.30±3.17 mSv(标准剂量7.16±4.61 mSv,p<0.001)。

核心结论

  • 低剂量MBIR CTE对克罗恩病活动性炎症改变的检测具有敏感性和特异性,且辐射剂量显著低于标准技术。

研究设计与样本

  • 前瞻性研究,共163例因克罗恩病评估转诊至医院放射科行CTE的患者,其中92例(56.4%)有活动性疾病。
  • 患者同日以随机顺序接受标准剂量CTE(生成滤过反投影和自适应统计迭代重建ASIR图像)和低剂量MBIR CTE。
  • 由两名放射科医生阅片评估小肠克罗恩病征象,以ASIR影像表现和临床疾病活动度评估作为参考标准。

诊断标准与关键数值

  • 以ASIR放射学标准为参考,极低剂量扫描的敏感度为0.85~0.94、特异度为0.84~0.97(取决于阅片者)。
  • MBIR与两种标准剂量技术非劣效,三种图像与临床参考标准比较均无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: CT enterography (CTE) is sensitive and specific for active inflammatory changes of Crohn disease (CD), but its use has been limited by exposure to ionizing radiation. The objective of this study is to show the noninferiority of a model-based iterative reconstruction (MBIR) technique using lower radiation doses compared with standard-dose CTE in the assessment of CD.

SUBJECTS AND METHODS: Patients referred to a hospital radiology department for CTE for the evaluation of CD underwent both a standard examination (used to generate filtered back-projection and adaptive statistical iterative reconstruction [ASIR] images) and low-dose MBIR CTE performed in a random sequence on the same day. Images were reviewed by two radiologists for signs of small-bowel CD. Radiologic findings obtained using ASIR and clinical assessments of disease activity served as the reference standard for comparison with low-dose CTE findings.

RESULTS: A total of 163 patients, 92 (56.4%) of whom had active disease, underwent CTE. MBIR was found to be noninferior to the two standard-dose techniques, with no significant differences noted between the three types of images when compared with the clinical reference standard. As compared with the radiologic standard of ASIR, the very-low-dose scans had a high degree of accuracy, with sensitivity ranging from 0.85 to 0.94 and specificity ranging from 0.84 to 0.97 depending on the reader. A significant reduction in radiation exposure was noted with MBIR (mean [± SD] reduction, 3.30 ± 3.17 mSv) versus standard-dose imaging (7.16 ± 4.61 mSv; p < 0.001).

CONCLUSION: Low-dose CTE using MBIR is sensitive and specific for the detection of active inflammatory changes of CD while utilizing radiation doses substantially lower than those associated with standard techniques.