降低CT辐射剂量的变异性:患者安全的新前沿
该研究通过建立辐射剂量优化委员会、标准化扫描协议和实施扫描仪软件,比较干预前后CT辐射剂量的变异性。干预前平均剂量为22.3 CTDIvol(SD 17.0),干预后为13.6 CTDIvol(SD 9.01),变异性显著降低(P < .0001)。
要点
- 标准化协议结合剂量管理软件可显著降低CT辐射剂量的变异性。
- 干预后平均CTDIvol从22.3降至13.6,标准差从17.0降至9.01。
- 辐射剂量优化委员会在降低剂量变异性中发挥监督作用。
核心结论
- 通过网络内标准化协议和实施有效管理辐射剂量的先进软件,并由辐射剂量优化委员会监督,实现了网络CT辐射剂量变异性的显著降低。
研究设计与样本
- 研究采用多层面方法降低CT辐射剂量变异性,包括建立辐射剂量优化委员会、标准化协议和实施扫描仪软件;收集干预前(2013年1月1日至2014年7月31日,n=39,314)和干预后(2016年1月1日至2016年12月31日,n=49,863)两个时期的数据,2014年8月1日至2015年12月31日为实施主要干预的时间段。
诊断标准与关键数值
- 干预前所有CT检查的平均辐射剂量为22.3 CTDIvol,标准差为17.0。
- 干预后所有CT检查的平均辐射剂量为13.6 CTDIvol,标准差为9.01。
- 干预后变异性显著降低(P < .0001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Although reducing radiation dose in CT examinations is an important goal, also important in the management of radiation dose is ensuring consistency of dose administered for a given type of examination. We have implemented an approach to reducing variance in CT radiation dose by standardizing protocols and implementing software that decreases variance.
METHODS: A multifaceted approach to reducing variance in CT radiation dose was utilized: (1) establishment of the Radiation Dose Optimization Committee, (2) standardization of protocols, and (3) implementation of scanner software. Two periods of data were collected: pre-intervention (January 1, 2013, to July 31, 2014) and postintervention (January 1, 2016, to December 31, 2016). The period from August 1, 2014, to December 31, 2015, represented the time the major interventions were performed.
RESULTS: The average radiation dose for all CT exams performed during the pre-intervention period (n = 39,314) was 22.3 CTDIvol with an SD of 17.0. The average radiation dose for all CT exams performed during the postintervention period (n = 49,863) was 13.6 CTDIvol with an SD of 9.01. The postintervention variance was significantly decreased (P < .0001).
CONCLUSIONS: A significant decrease in the variability of our network CT radiation dose was achieved as a result of a combination of standardizing protocols across the network and implementation of advanced software that effectively managed radiation dose, all overseen by the Radiation Dose Optimization Committee.
引用
- Lee RK, Sun JY, Lockerby S, et al. Reducing Variability of Radiation Dose in CT: The New Frontier in Patient Safety. J Am Coll Radiol. 2017. PMID: 29203306. doi:10.1016/j.jacr.2017.10.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。