超声测定股骨头颈α角
研究纳入28例因髋部CT检查的患者,共39个髋,比较超声与CT测量的股骨头颈α角。CT平均62.5°(±14.2°),超声平均64.5°(±12.6°),平均绝对差10.5°(95%CI 6.9°-14.0°)。超声敏感度91.3%、特异度43.75%、阳性预测值0.7、阴性预测值0.78、总准确率0.718。
要点
- 超声测量股骨头颈α角与CT相比敏感度91.3%,但特异度仅43.75%。
- 超声阴性预测值0.78,阴性结果对排除凸轮型撞击有一定价值。
- 超声测量α角可为有症状患者提供凸轮型股骨髋臼撞击的客观证据。
核心结论
- 超声测量股骨头颈α角与CT相比具有良好敏感度和阴性预测值,但特异度低;可为有症状患者提供凸轮型股骨髋臼撞击的客观证据,并可将患者导向更成熟的影像技术。
研究设计与样本
- 研究论文;从因髋部CT检查就诊的队列中招募患者,共28例、39个髋(11例双侧),女15例、男13例,右髋21个、左髋18个,平均年龄40岁(±13.9岁);CT后行超声检查,由对CT结果不知情的超声医师测量α角;采用Bland-Altman检验比较两种方法,P<0.05为显著。
诊断标准与关键数值
- CT测量α角均值62.5°(±14.2°),超声测量均值64.5°(±12.6°),两种方法平均绝对差10.5°(95%CI 6.9°-14.0°);超声单次测量敏感度91.3%,特异度43.75%,阳性预测值0.7,阴性预测值0.78,总准确率0.718。
临床应用与阅片要点
- 超声测量α角可用于有症状患者凸轮型股骨髋臼撞击的客观证据,并可据此将患者导向更成熟的影像技术。
- 超声特异度低(43.75%),阳性结果需结合其他影像学检查确认。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The femoral head-neck alpha angle is used to quantify the degree of femoral head asphericity in patients suspected of cam-type femoroacetabular impingement. The measurement was first performed using magnetic resonance imaging and, more recently, three-dimensional computed tomography (CT). We set out to determine whether the alpha angle could be reliably measured using ultrasound. Patients were recruited from a cohort presenting for CT of the hip. Alpha angles were calculated following the departmental protocol by institutionally accredited radiographers. After the CT, patients were imaged with ultrasound and the alpha angle calculated from the ultrasound image by a sonographer blinded to the CT result. Statistical comparison of the two methods was performed with the Bland-Altman test using SPSS (version 21.0, Chicago, USA), and a p < 0.05 afforded significance. Twenty-eight patients were recruited. Eleven patients were bilateral examinations, providing 39 hips for analysis. There were 15 females and 13 males, with 21 right and 18 left hips examined. Average patient age (±standard deviation) was 40 y (±13.9 y). Mean (±standard deviation) measurements for CT and ultrasound were 62.5° (±14.2°) and 64.5° (±12.6°), respectively. The mean absolute difference between the two methods was 10.5° (95% confidence interval 6.9°-14.0°). Sensitivity of each individual ultrasound measurement was 91.3%. The specificity of ultrasound was 43.75%. The positive predictive value was 0.7, and the negative predictive value was 0.78. Overall accuracy of the ultrasound-derived alpha angle was calculated at 0.718. Ultrasound demonstrates good sensitivity and good negative predictive value in calculation of the femoral head-neck alpha angle compared with CT; however, specificity is low. Ultrasound measurement of the alpha angle can provide objective evidence of cam-type femoroacetabular impingement in symptomatic patients and can direct patients to more established imaging techniques where appropriate.
引用
- Robinson DJ, Lee S, Marks P, et al. Ultrasound Determination of the Femoral Head-Neck Alpha Angle. Ultrasound Med Biol. 2017. PMID: 29195753. doi:10.1016/j.ultrasmedbio.2017.10.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。