文献速递头颈甲状腺与浅表US

实时与静态超声对甲状腺结节评估的检查间一致性和韩国甲状腺影像报告与数据系统的诊断性能比较

Inter-exam agreement and diagnostic performance of the Korean thyroid imaging reporting and data system for thyroid nodule assessment: Real-time versus static ultrasonography.
PubMed 文献 · Eur J Radiol · 2017-10-31

研究纳入253个结节(238例患者)评估实时超声评估与回顾性静态图像解读之间的检查间一致性,另纳入201个结节(190例患者)比较两种方法基于K-TIRADS的诊断性能。结果显示总体检查间一致性几乎完美至极佳,各描述词和最终K-TIRADS分类的κ值为0.666-0.868,两种方法的整体诊断性能相当。

要点

  • 实时超声与回顾性静态图像解读对甲状腺结节的K-TIRADS分类一致性达到显著水平以上(最终分类κ=0.754)。
  • 取向的一致性几乎完美(κ=0.868),成分、海绵样外观、回声、形状、边缘、钙化的一致性为显著(κ=0.666-0.786)。
  • 实时超声评估与回顾性图像解读使用K-TIRADS的整体诊断性能相当。

核心结论

  • 使用K-TIRADS时,实时超声评估与回顾性静态图像解读对甲状腺结节的总体检查间一致性等于或高于显著水平,两种方法的整体诊断性能相当,K-TIRADS可提供一致的描述和评估,不受解读时机影响。

研究设计与样本

  • 研究纳入253个结节(238例患者)用于检查间一致性分析,201个结节(190例患者)用于诊断性能分析;实时超声评估与回顾性静态超声图像均依据K-TIRADS的超声描述词和最终分类进行分析。

关键影像表现/征象

  • 取向的检查间一致性几乎完美(κ=0.868)。
  • 成分、海绵样外观、回声、形状、边缘、钙化及最终K-TIRADS分类的检查间一致性为显著(κ分别为0.754、0.786、0.747、0.670、0.666、0.778、0.754)。
  • 以囊性为主成分和边缘模糊的检查间一致性为中等。

诊断标准与关键数值

  • 实时超声评估与回顾性静态图像解读使用K-TIRADS的整体诊断性能相当。

临床应用与阅片要点

  • 日常阅片中按K-TIRADS描述词和分类进行实时评估或回顾性图像解读,可获得等于或高于显著水平的一致性。
  • 以囊性为主成分和边缘模糊这两个征象的检查间一致性为中等,解读时需注意。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the inter-exam agreement for thyroid nodule between real-time ultrasonography (US) assessment and retrospective US interpretation and to compare the diagnostic performance between two methods by using the most recently published guidelines for the US-based management of thyroid nodules, the Korean Thyroid Imaging Reporting and Data System (K-TIRADS).

METHODS: The study included 253 nodules in 238 patients for the inter-exam agreement and 201 nodules in 190 patients for the diagnostic performance. Real-time and retrospectively static US images were analyzed according to the US descriptors and final categories of the K-TIRADS. Inter-exam agreements between real-time US assessments and static US image interpretation were analyzed, as was the diagnostic performance of both methods.

RESULTS: Overall inter-exam agreements were almost perfect for orientation (κ=0.868); and substantial for composition, spongiform appearance, echogenicity, shape, margin, calcification, and final K-TIRADS categories (κ=0.754, 0.786, 0.747, 0.670, 0.666, 0.778, and 0.754, respectively). Specifically, moderate agreements were observed for predominantly cystic composition and ill-defined margin. The overall diagnostic performances of both real-time US assessment and retrospective US interpretation using the K-TIRADS were comparable.

CONCLUSIONS: Overall inter-exam agreements between real-time and retrospective US image interpretation for thyroid nodules using the K-TIRADS were equal or more than a substantial. Therefore, the use of K-TIRADS can provide consistent description and assessment for thyroid US regardless of the timing of interpretation.

来源:Eur J Radiol,查看原文。版权归原作者所有。