三维THRIVE MRI、二维自旋回波MRI与增强CT检测颈部转移性未知原发肿瘤患者临床隐匿原发灶的比较
研究纳入73例内镜或体格检查未发现原发灶的颈部淋巴结转移患者,术前行增强CT及MRI(自旋回波T1WI和三维THRIVE序列),以引导活检结果为参考标准。三维THRIVE检测原发灶的敏感度72.9%和准确率71.2%高于自旋回波T1WI(49.2%和53.4%)及CT(36.4%和46.4%),特异度无差异,AUC无差异。三维THRIVE可能改善此类患者的活检和治疗计划。
要点
- 三维THRIVE检测隐匿原发灶的敏感度72.9%,高于自旋回波T1WI的49.2%和CT的36.4%。
- 三维THRIVE准确率71.2%,高于自旋回波T1WI的53.4%和CT的46.4%。
- 三种方法特异度无差异,AUC亦无差异。
核心结论
- 在颈部转移性未知原发肿瘤患者中,三维THRIVE检测原发灶的敏感度高于自旋回波T1WI和CT,该序列可能改善活检和治疗计划。
研究设计与样本
- 连续纳入73例内镜或体格检查未发现原发灶的颈部淋巴结转移患者,术前行增强CT和MRI(自旋回波T1WI及三维THRIVE序列),以引导活检结果为参考标准,采用McNemar检验比较诊断性能。
关键影像表现/征象
- 术后59例(80.8%)患者发现原发灶,其中扁桃体36例、舌根11例、鼻咽7例、梨状窝5例。
诊断标准与关键数值
- 三维THRIVE检测原发灶的敏感度72.9%、准确率71.2%。
- 自旋回波T1WI检测原发灶的敏感度49.2%、准确率53.4%。
- CT检测原发灶的敏感度36.4%、准确率46.4%。
- 三维THRIVE的AUC为0.681,自旋回波T1WI为0.671,CT为0.608,三者差异无统计学意义(p>0.05)。
临床应用与阅片要点
- 作者认为三维THRIVE序列可能改善此类患者的活检和治疗计划。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate and compare the utility of contrast-enhanced three-dimensional (3D) T1-weighted high-resolution isotropic volume examination (THRIVE), spin-echo (SE) T1-weighted magnetic resonance imaging (MRI), and computed tomography (CT) for detecting clinically occult primary tumours in patients with cervical lymph node metastases.
MATERIALS AND METHODS: Seventy-three consecutive patients with tumours that went undetected during endoscopic or physical examinations underwent preoperative contrast-enhanced CT and MRI (SE and 3D THRIVE) after gadolinium injection. Guided biopsy results served as reference standards. The diagnostic performances of the imaging techniques were compared with McNemar's tests.
RESULTS: Primary tumours were identified in 59 (80.8%) of the 73 patients after surgery. Of these, 36 were found in the palatine tonsil, 11 in the base of the tongue, seven in the nasopharynx, and five in the pyriform sinus. The sensitivity (72.9%) and accuracy (71.2%) of 3D THRIVE for detecting primary tumours were higher than were those of SE T1-weighted MRI (49.2% and 53.4%, p≤0.002) or CT (36.4% and 46.4%, p≤0.001). The specificities of these techniques did not differ. The diagnostic performance of 3D THRIVE (area under the curve [AUC]=0.681) for detecting tumours did not differ from that of SE T1-weighted MRI or CT (AUC=0.671 and 0.608, p>0.05).
CONCLUSION: 3D THRIVE was more sensitive at detecting primary tumours than was SE T1-weighted MRI or CT in patients with cervical metastases of unknown primary tumours. This sequence may improve biopsy and therapeutic planning in these patients.
引用
- Yoo MG, Kim J, Bae S, et al. Detection of clinically occult primary tumours in patients with cervical metastases of unknown primary tumours: comparison of three-dimensional THRIVE MRI, two-dimensional spin-echo MRI, and contrast-enhanced CT. Clin Radiol. 2017. PMID: 29195660. doi:10.1016/j.crad.2017.10.020