该随机前瞻性研究纳入156例患者共156个甲状腺结节,每个结节分别用23G、25G和27G针头穿刺,由2名细胞病理学家独立评估标本 adequacy。三种针头的标本合格率无统计学显著差异(88.5%、90.4%、89.7%,P > .05);高回声结节的合格率高于低回声结节(P < .05),结节大小对合格率无显著影响(P > .05)。作者结论认为27G针头可获取足以用于细胞病理学诊断的标本,低回声结节获取不合格材料的可能性高于高回声结节。

要点

  • 23G、25G、27G针头甲状腺结节细针穿刺的标本合格率无统计学显著差异(88.5%、90.4%、89.7%,P > .05)。
  • 高回声结节的标本合格率高于低回声结节(P < .05),低回声结节更易获取不合格材料。
  • 结节大小对三种针头的标本合格率无显著影响(P > .05)。

核心结论

  • 27G针头细针穿刺活检可获取足以用于甲状腺结节细胞病理学诊断的标本;低回声结节获取不合格材料的可能性高于高回声结节。

研究设计与样本

  • 随机前瞻性研究,连续纳入156例患者共156个甲状腺结节,每个结节分别用23G、25G和27G针头穿刺,标本由2名细胞病理学家独立分析并计算合格率。

关键影像表现/征象

  • 高回声结节的标本合格率高于低回声结节(P < .05)。
  • 不同针头口径的标本合格率在结节大小各亚组间无显著差异(P > .05)。

诊断标准与关键数值

  • 23G针头标本合格率88.5%,25G为90.4%,27G为89.7%,三者间无统计学显著差异(P > .05)。
  • 高回声结节与低回声结节的标本合格率差异有统计学意义(P < .05),高回声结节合格率更高。
  • 按结节大小分层,不同针头口径的标本合格率无显著差异(P > .05)。

临床应用与阅片要点

  • 作者结论认为27G针头细针穿刺活检可获取足以用于甲状腺结节细胞病理学诊断的标本。
  • 作者指出低回声结节获取不合格材料的可能性高于高回声结节。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the adequacy of 23-, 25-, and 27-gauge needles in the fine-needle aspiration biopsy of thyroid nodules to develop guidelines for the collection of better specimens for cytologic diagnosis.

METHODS: This randomized prospective study included 156 consecutively enrolled patients with 156 nodules. Each nodule was aspirated with a needle of each size. The obtained specimens were analyzed independently by 2 cytopathologists, and adequacy rates were calculated.

RESULTS: In our investigation, there were no statistically significant differences among the adequacy rates achieved with 23-, 25-, and 27-gauge needles (88.5%, 90.4%, and 89.7%, respectively; P > .05). The adequacy rates achieved with all 3 needle sizes in hyperechoic nodules were higher than those in hypoechoic samples (P < .05). Finally, no differences in adequacy for the different needle sizes were observed according to nodule size (P > .05).

CONCLUSIONS: We conclude that fine-needle aspiration biopsy with a 27-gauge needle can aspirate an adequate specimen for cytopathologic diagnosis of thyroid nodules. The likelihood that inadequate materials will be obtained from hypoechoic nodules is higher than that for hyperechoic nodules.