乳腺X线摄影与数字乳腺断层摄影筛查检出癌及间期癌的乳腺癌特征比较
研究比较二维数字乳腺摄影(DM)与数字乳腺断层摄影(DBT)筛查检出癌及间期癌的率和肿瘤特征,共纳入78 385次DM和76 896次DBT检查后诊断的948例乳腺癌;DBT组筛查检出癌中浸润性癌比例高于DM组(74.2% vs 66.0%,P=.01),两组筛查检出癌总率(5.0 vs 5.0/1000,P=.98)及间期癌率(1.1 vs 1.1/1000,P=.84)相似。
要点
- DBT组筛查检出癌中浸润性癌占比高于DM组(74.2% vs 66.0%,P=.01)。
- 两组筛查检出癌总率相似(5.0 vs 5.0/1000次检查,P=.98)。
- 两组间期癌率相似(1.1 vs 1.1/1000次检查,P=.84)。
核心结论
- DM与DBT的筛查检出癌总率和间期癌率相似,但DBT组筛查检出癌中浸润性癌而非原位癌的比例更高。
研究设计与样本
- 连续筛查乳腺X线摄影回顾性分析,DM组为2009年1月至2011年2月(DBT整合前),DBT组为2013年1月至2015年2月(DBT完全整合后),共78 385次DM和76 896次DBT检查后诊断948例乳腺癌;筛查检出癌指阳性筛查检查后365天内诊断,间期癌指阴性筛查检查后365天内诊断;采用Z检验比较DM与DBT。
诊断标准与关键数值
- 筛查检出癌率:DM组5.0/1000次检查 vs DBT组5.0/1000次检查(P=.98)。
- 筛查检出癌中浸润性癌比例:DBT组74.2%(287/387) vs DM组66.0%(260/394),P=.01。
- 间期癌率:DM组1.1/1000次检查 vs DBT组1.1/1000次检查(P=.84)。
- 筛查检出浸润性癌的肿瘤特征(病理大小、分级、激素受体状态、淋巴结状态)在DM与DBT间无显著差异(P=.09-.99)。
临床应用与阅片要点
- 筛查检出癌的定义为阳性筛查检查后365天内诊断,间期癌为阴性筛查检查后365天内诊断。
- 与有症状的间期癌相比,磁共振成像检出的间期癌更可能为微小癌。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To determine whether the rates and tumor characteristics of screening-detected and interval cancers differ for two-dimensional digital mammography (DM) versus digital breast tomosynthesis (DBT) mammography. Materials and Methods Consecutive screening mammograms from January 2009 to February 2011 (DM group, before DBT integration) and from January 2013 to February 2015 (DBT group, after complete DBT integration) were reviewed. Cancers were considered screening detected if diagnosed within 365 days of a positive screening examination and interval if diagnosed within 365 days of a negative screening examination. Z tests were used to compare cancers on DM versus DBT examinations. Results A total of 948 breast cancers were diagnosed after 78 385 DM and 76 896 DBT examinations. Although the overall rate of screening-detected cancers was similar with DM and DBT (5.0 vs 5.0 per 1000 examinations, P = .98), a higher proportion of screening-detected cancers were invasive rather than in situ with DBT (74.2% [287 of 387] vs 66.0% [260 of 394], P = .01). There were no significant differences in tumor characteristics, including size at pathologic examination, grade, hormone receptor status, and nodal status, between the screening-detected invasive cancers on DM versus DBT (P = .09-.99). The rate of interval cancers was similar with DM and DBT (1.1 vs 1.1 per 1000 examinations, P = .84). Compared with symptomatic interval cancers, magnetic resonance imaging-detected interval cancers were more likely to be minimal cancers. Conclusion The overall rates of screening-detected and interval cancers are similar with DM and DBT, but a higher proportion of screening-detected cancers are invasive rather than in situ with DBT. © RSNA, 2017.