18F-氟脱氧葡萄糖标本正电子发射乳腺摄影在保乳手术中描绘肿瘤范围:初步结果
本研究纳入16例患者,在保乳手术中利用残留18F-FDG摄取对切除标本行高分辨率标本-PEM扫描,评估肿瘤范围并测量医护人员辐射暴露。标本-PEM对浸润性病变检出率100%(12/12),原位病变检出率94.4%(17/18),医护人员平均暴露为18 μSv,结论认为标本-PEM检测浸润性和原位病变准确性高且辐射暴露可接受。
要点
- 标本-PEM对浸润性病变检出率100%(12/12),对原位病变检出率94.4%(17/18)。
- 标本-PEM预测切缘阴性的准确性与术中冰冻切片分析相同。
- 保乳手术中18F-FDG注射后医护人员平均辐射暴露为18 μSv。
核心结论
- 标本-PEM检测浸润性和原位病变准确性高,且医护人员辐射暴露在可接受范围内。
研究设计与样本
- 初步研究,纳入16例患者,同日行正电子发射断层扫描后保乳手术及术中冰冻切片分析,切除标本行高分辨率标本-PEM扫描;术后至少1天由三名独立经验丰富的阅片者及二值化图像评估肿瘤范围;测量医护人员术中18F-FDG暴露。
诊断标准与关键数值
- 标本-PEM二值化图像和三名阅片者两种方法均检出全部浸润性病变(100%,12/12)和94.4%(17/18)的原位病变;累积病变的阳性预测值二值化图像为74.4%(29/39),三名阅片者为82.9%(29/35);术中冰冻切片分析检出100%(2/2)的切缘阳性病例,两种标本-PEM评估方法均检出且无假阳性切缘病例;医护人员平均18F暴露为18 μSv。
局限性
- 原文为初步结果(Preliminary results)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: We aimed to determine whether high-resolution specimen-positron emission mammography (PEM) using fluorodeoxyglucose (18F-FDG) can reveal extension of breast cancer in breast-conserving surgery (BCS), and assess the safety of radiation exposure to medical staff.
METHODS: Sixteen patients underwent positron emission tomography, and then BCS with intraoperative frozen section analysis on the same day. Resected specimens with remaining 18F-FDG accumulation were scanned by high-resolution PEM. At least 1 day after surgery, tumour extension was evaluated by three independent experienced readers and by binarized images from the specimen-PEM data. Intraoperative exposure of medical staff to 18F-FDG was measured.
RESULTS: Specimen-PEM evaluations of binarized images and the three investigators detected all (100 %, 12/12) invasive lesions and 94.4 % (17/18) of in situ lesions using both methods. The positive predictive value of the accumulated lesions was 74.4 % (29/39) for the binarized images and 82.9 % (29/35) for the three investigators. Analysis of intraoperative frozen sections detected 100 % (2/2) of the margin-positive cases, also detected by both specimen-PEM evaluation methods with no false-positive margin cases. The mean exposure of the medical staff to 18F was 18 μSv.
CONCLUSIONS: Specimen-PEM detected invasive and in situ lesions with high accuracy and allowable radiation exposure.
KEY POINTS: • Specimen-PEM detected invasive and in situ lesions with high accuracy. • Specimen-PEM predicted complete resection with the same accuracy as frozen section analysis. • Breast-conserving surgery after fluorodeoxyglucose injection was performed with low medical staff exposure.
引用
- Watanabe G, Itoh M, Duan X, et al. 18F-fluorodeoxyglucose specimen-positron emission mammography delineates tumour extension in breast-conserving surgery: Preliminary results. Eur Radiol. 2017. PMID: 29218614. doi:10.1007/s00330-017-5170-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。