文献速递乳腺US

影响乳腺准静态超声弹性成像图质量的因素

Factors Affecting the Quality of Breast Quasistatic Ultrasound Elastograms.
PubMed 文献 · J Ultrasound Med · 2017-12-30

研究纳入663例患者共702个乳腺病灶,行常规超声与准静态弹性成像,按弹性图满意与否分为A组(590个满意)和B组(112个不满意),比较病灶最大深度、最大横径、脂肪层厚度、腺体层厚度、乳腺厚度、乳头-病灶距离、年龄、体质指数及绝经状态。B组病灶更深、最大横径更大、脂肪层更厚、腺体层更厚、乳腺更厚(P < .05);多因素logistic回归显示病灶最大深度、脂肪层厚度及乳腺厚度为弹性图质量的独立因素,病灶最大深度曲线下面积为0.986,最佳截断阈值2.5 cm。结论认为准静态弹性成像可作为常规超声的补充方法帮助提高乳腺病灶诊断准确性,病灶深度和大小与弹性图质量相关。

要点

  • 病灶最大深度、脂肪层厚度及乳腺厚度是准静态弹性图质量的独立影响因素。
  • 病灶最大深度鉴别弹性图质量的曲线下面积为0.986,最佳截断阈值2.5 cm。
  • B组(弹性图不满意)病灶更深、最大横径更大、脂肪层及腺体层更厚、乳腺更厚(P < .05)。

核心结论

  • 准静态弹性成像可作为常规超声的补充方法,帮助提高乳腺病灶的诊断准确性。
  • 乳腺病灶的深度和大小与弹性图质量相关。

研究设计与样本

  • 研究类型为探索影响乳腺准静态超声弹性图质量因素的临床研究。
  • 共纳入663例患者、702个乳腺病灶,全部接受常规超声和准静态弹性成像检查。
  • 按弹性图满意与否分为A组(590个满意弹性图)和B组(112个不满意弹性图)。

诊断标准与关键数值

  • 病灶最大深度鉴别弹性图质量的曲线下面积为0.986,最佳截断阈值为2.5 cm。
  • 多因素logistic回归分析显示病灶最大深度、脂肪层厚度和乳腺厚度为弹性图质量的独立因素。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To explore factors affecting the quality of quasistatic ultrasound elastograms of the breast and to evaluate their accuracy in distinguishing benign and malignant breast lesions.

METHODS: A total of 663 patients with 702 breast lesions were recruited. All patients received both conventional ultrasonography and quasistatic elastography. Patients' breast lesions were divided into A and B groups according to satisfactory and unsatisfactory elastographic examinations. Group A included 590 satisfactory elastograms, whereas Group B included 112 unsatisfactory elastograms. Various factors-maximum depth of the lesion, maximum transverse diameter of the lesion, thickness of the adipose layer, thickness of the glandular layer, thickness of the breast, distance between the nipple and lesion, age, body mass index, and menopausal status-were analyzed and compared between the groups to gauge their effects on the quality of the elastograms.

RESULTS: Significantly deeper lesions, higher maximum transverse lesion diameters, thicker adipose layers, thicker glandular layers, and thicker breasts were identified in group B patients compared to group A patients (P < .05). Multivariate logistic regression analyses showed that the maximum depth of the lesion, thickness of the adipose layer, and thickness of the breast were independent factors in the quality of elastograms. The area under the curve for the maximum depth of the lesion was 0.986 with the optimal cutoff threshold of 2.5 cm.

CONCLUSIONS: Quasistatic elastography can be a supplementary approach to conventional ultrasonography in helping improve the diagnostic accuracy of breast lesions. The depth and size of breast lesions are correlated with the quality of elastograms.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Zou H, Xue Y, Ou Y, et al. Factors Affecting the Quality of Breast Quasistatic Ultrasound Elastograms. J Ultrasound Med. 2017. PMID: 29288591. doi:10.1002/jum.14518

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。