角度无关三维超声评价子痫前期脐静脉血体积流量
研究纳入35例单胎妊娠孕妇,其中子痫前期5例、高危组26例中的子痫前期患者、正常妊娠9例,采用2.0-8.0 MHz探头三维彩色血流与能量模式数据计算脐静脉平均体积流量。结果显示子痫前期孕妇深度校正、体重归一化脐静脉体积流量较正常妊娠显著降低(P = .035),测量重复性高,作者鼓励在更大临床人群中进一步研究。
要点
- 深度校正、体重归一化脐静脉体积流量在子痫前期组较正常妊娠组显著降低(P = .035)。
- 体重归一化流量在两组间分离度中等偏高但未达统计学显著(P = .11)。
- 脐静脉体积流量测量重复性高,患者内相对SE为12.1%±5.9%。
核心结论
- 结果提示子痫前期妊娠中深度校正、体重归一化平均脐静脉体积流量降低,且体积流量可能更早提示妊娠期高血压疾病。
研究设计与样本
- 共纳入35例单胎妊娠孕妇,其中子痫前期5例(取自26例高危组的子集)、正常妊娠9例;使用配备2.0-8.0 MHz探头的超声系统采集多体积三维彩色血流与能量模式数据集。
诊断标准与关键数值
- 正常妊娠组与子痫前期组比较:体重归一化流量组间分离度中等偏高(P = .11),深度校正、体重归一化流量组间差异有统计学意义(P = .035)。
临床应用与阅片要点
- 作者鼓励在更大临床人群中进一步研究,以确定三维体积流量能否辅助子痫前期及一般高危妊娠的管理。
局限性
- 原文结论指出需在更大临床人群中进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the association between umbilical vein blood volume flow and the condition of preeclampsia in an at-risk maternal patient cohort. Umbilical vein volume flow was quantified by a 3-dimensional (3D) sonographic technique that overcomes several limitations of standard sonographic flow measurement methods.
METHODS: A total of 35 patients, each with a singleton pregnancy, were recruited to provide 5 patients with preeclampsia, derived as a subset from a 26-patient at-risk group, and 9 patients with normal pregnancies. An ultrasound system equipped with a 2.0-8.0-MHz transducer was used to acquire multivolume 3D color flow and power mode data sets to compute the mean umbilical vein volume flow in patients with normal pregnancies and preeclampsia.
RESULTS: The gestational ages of the pregnancies ranged from 29.7 to 34.3 weeks in the patients with preeclampsia and from 25.9 to 34.7 weeks in the patients with normal pregnancies. Comparisons between patients with normal pregnancies and those with preeclampsia showed weight-normalized flow with a moderately high separation between groups (P = .11) and depth-corrected, weight-normalized flow with a statistically significant difference between groups (P = .035). Umbilical vein volume flow measurements were highly reproducible in the mean estimate, with an intrapatient relative SE of 12.1% ± 5.9% and an intrameasurement relative SE of 5.6% ± 1.9 %. In patients who developed pregnancy-induced hypertension or severe pregnancy-induced hypertension, umbilical vein volume flow suggested gestational hypertensive disorder before clinical diagnosis.
CONCLUSIONS: Results indicate that mean depth-corrected, weight-normalized umbilical vein volume flow is reduced in pregnancies complicated by preeclampsia and that volume flow may indicate hypertensive disorder earlier in gestation. Volume flow measurements are highly reproducible, and further study in a larger clinical population is encouraged to determine whether 3D volume flow can complement the management of preeclampsia and, in general, at-risk pregnancy.
引用
- Pinter SZ, Kripfgans OD, Treadwell MC, et al. Evaluation of Umbilical Vein Blood Volume Flow in Preeclampsia by Angle-Independent 3D Sonography. J Ultrasound Med. 2017. PMID: 29243838. doi:10.1002/jum.14507
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。