文献速递妇产影像介入MRUS

定量DCE参数对症状性子宫肌瘤高强度聚焦超声消融即时治疗反应的预测价值

The predictive value of quantitative DCE metrics for immediate therapeutic response of high-intensity focused ultrasound ablation (HIFU) of symptomatic uterine fibroids.
PubMed 文献 · Abdom Radiol (NY) · 2018-01-01

研究纳入65例患者共78个症状性子宫肌瘤,于US-HIFU治疗前1天和治疗后3天行常规MRI及DCE-MRI,评估定量DCE参数预测即时无灌注体积比(NPVR)的价值;结果显示治疗前Ktrans、BF、BV值越高,NPVR越低,联合Ktrans与BF预测NPVR的AUC达0.922。

要点

  • 治疗前DCE-MRI的Ktrans、BF、BV值越高,HIFU即时消融效果越差(NPVR越低)。
  • Ktrans联合BF预测即时NPVR的AUC为0.922,优于单一参数。
  • 每例计算DCE参数平均耗时7.5分钟,软件操作简便快速。

核心结论

  • 基线DCE-MRI的Ktrans、BF和BV值较高提示HIFU对症状性子宫肌瘤的消融效果较差,治疗前DCE-MRI参数可能是有用的预测消融效果的生物标志物。

研究设计与样本

  • 研究纳入65例女性患者的78个症状性子宫肌瘤,均接受US-HIFU治疗,治疗前1天和治疗后3天行常规MRI和DCE-MRI扫描,测量治疗前渗透性参数Ktrans、Kep、Ve、Vp及T1灌注参数BF、BV,以NPVR评估即时消融效率,按NPVR≥70%和NPVR<70%分组比较预测性能。

诊断标准与关键数值

  • NPVR≥70%组的治疗前Ktrans、Kep、Ve和BF值显著低于NPVR<70%组(p<0.05);即时NPVR与治疗前Ktrans、BF、BV值呈负相关(r分别为-0.561、-0.712、-0.528,p均<0.05);治疗前Ktrans、BF、BV值及Ktrans联合BF预测即时NPVR的AUC分别为0.810、0.909、0.795、0.922(p均<0.05)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study was to investigate the value of quantitative DCE-MRI parameters for predicting the immediate non-perfused volume ratio (NPVR) of HIFU therapy in the treatment of symptomatic uterine fibroids.

MATERIALS AND METHODS: A total of 78 symptomatic uterine fibroids in 65 female patients were treated with US-HIFU therapy. All patients underwent conventional MRI and DCE-MRI scans 1 day before and 3 days after HIFU treatment. Permeability parameters K trans, K ep, V e, and V p and T1 perfusion parameters BF and BV of pretreatment were measured as a baseline, while NPVR was used to assess immediate ablation efficiency. Data were assigned to NPVR ≧ 70% and NPVR < 70% groups. Then, the predictive performances of different parameters for ablation efficacy were studied to seek the optimal cut-off value, and the length of time to calculate the variable parameters in each case was recorded.

RESULTS: (1) It was observed that the pretreatment K trans, K ep, V e, and BF values of the NPVR ≧ 70% group were significantly lower compared to the NPVR < 70% group (p < 0.05). (2) The immediate NPVR was negatively correlated with the K trans, BF, and BV values before HIFU treatment (r = - 0.561, - 0.712, and - 0.528, respectively, p < 0.05 for all). (3) The AUCs of pretreatment K trans, BF, BV values, and K trans combined with BF used to predict the immediate NPVR were 0.810, 0.909, 0.795, and 0.922, respectively (p < 0.05 for all). (4) The mean time to calculate the variable parameters in each case was 7.5 min.

CONCLUSION: Higher K trans, BF, and BV values at baseline DCE-MRI suggested a poor ablation efficacy of HIFU therapy for symptomatic uterine fibroids, while the pretreatment DCE-MRI parameters could be useful biomarkers for predicting the ablation efficacy in select cases. The software used to calculate DCE-MRI parameters was simpler, quicker, and easier to incorporate into clinical practice.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Wei C, Fang X, Wang CB, et al. The predictive value of quantitative DCE metrics for immediate therapeutic response of high-intensity focused ultrasound ablation (HIFU) of symptomatic uterine fibroids. Abdom Radiol (NY). 2018. PMID: 29204677. doi:10.1007/s00261-017-1426-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。