子宫内膜癌:扩散加权成像的诊断准确性及其与Ki-67表达的相关性

Endometrial carcinoma: diffusion-weighted imaging diagnostic accuracy and correlation with Ki-67 expression.
PubMed 文献 · Clin Radiol · 2017-12-12

前瞻性纳入52例经盆腔MRI检查的浸润性癌患者,采用b值0和1000 s/mm²的DWI测量ADC值,并与组织学Ki-67表达进行相关性分析。子宫内膜癌在DWI上呈高信号者占92.3%(48/52),癌组织平均ADC值显著高于正常子宫内膜间质(1.39±0.27×10⁻³ vs 0.93±0.21×10⁻³ mm²/s,p<0.001),且ADC值与Ki-67表达呈显著负相关(r=-0.82,p<0.001)。结论认为ADC值有助于判断肿瘤分级、分期和增殖活性。

要点

  • 子宫内膜癌在DWI上多表现为高信号,本组检出率为92.3%(48/52)。
  • 癌组织平均ADC值显著高于正常子宫内膜间质(1.39±0.27×10⁻³ vs 0.93±0.21×10⁻³ mm²/s,p<0.001)。
  • ADC值与Ki-67表达呈显著负相关(r=-0.82,p<0.001),高Ki-67表达者ADC值更低。

核心结论

  • ADC值是协助判断子宫内膜癌分级、分期和增殖活性的有用参数,可能进一步改善患者预后并有助于制定更有效的治疗方案。

研究设计与样本

  • 前瞻性研究,纳入52例经盆腔MRI检查的浸润性癌患者,采用b值为0和1000 s/mm²的DWI测量ADC值,并以组织学免疫组化Ki-67表达作为参考标准进行分析。

关键影像表现/征象

  • 子宫内膜癌在DWI上表现为高信号区,检出率为92.3%(48/52)。
  • 癌组织平均ADC值为1.39±0.27×10⁻³ mm²/s,正常子宫内膜间质为0.93±0.21×10⁻³ mm²/s,癌组织显著高于正常间质(p<0.001)。
  • 分级1级患者平均ADC值为1.01±0.16×10⁻³ mm²/s,显著高于3级患者的0.83±0.21×10⁻³ mm²/s(p<0.05)。
  • 分期IB患者平均ADC值为0.86±0.16×10⁻³ mm²/s,显著低于IA期患者的1.04±0.21×10⁻³ mm²/s(p<0.01)。
  • 高Ki-67表达患者平均ADC值为0.82±0.12×10⁻³ mm²/s,显著低于低Ki-67表达患者的1.16±0.12×10⁻³ mm²/s(p<0.001)。

诊断标准与关键数值

  • DWI采用b值为0和1000 s/mm²,测量ADC值用于比较子宫内膜癌与正常子宫内膜间质。
  • 子宫内膜癌DWI高信号检出率为92.3%(48/52)。
  • 癌组织与正常子宫内膜间质平均ADC值分别为1.39±0.27×10⁻³和0.93±0.21×10⁻³ mm²/s(p<0.001)。
  • 平均ADC值与Ki-67表达呈显著负相关(r=-0.82,p<0.001)。

临床应用与阅片要点

  • 在盆腔MRI阅片时,可将DWI高信号作为提示子宫内膜癌的征象之一(本组检出率92.3%)。
  • 测量ADC值有助于区分子宫内膜癌与正常子宫内膜间质,癌组织ADC值更高(1.39±0.27×10⁻³ vs 0.93±0.21×10⁻³ mm²/s,p<0.001)。
  • ADC值越低,提示肿瘤分级越高(3级低于1级,p<0.05)和分期越晚(IB期低于IA期,p<0.01)。
  • ADC值越低,提示Ki-67表达越高(高表达者0.82±0.12×10⁻³ vs 低表达者1.16±0.12×10⁻³ mm²/s,p<0.001),可能反映增殖活性更强。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the role of diffusion-weighted imaging (DWI) in the detection of endometrial carcinoma and to correlate the apparent diffusion coefficient (ADC) value with Ki-67 expression.

MATERIALS AND METHODS: Fifty-two patients with invasive cancer who underwent pelvic MRI were prospectively evaluated using DWI with b-values of 0 and 1000 s/mm2.The ADC values from standard DWI were measured. The expression of Ki-67 in histological specimens was analysed using immunohistochemistry. The ADC values of endometrial carcinoma and normal endometrial parenchyma were compared. Relationships between ADC values and Ki-67 expression were determined using Wilcoxon's signed rank test and the Kruskal-Wallis test.

RESULTS: Endometrial carcinoma was detected at DWI as a hyperintense area in 92.3% (48/52) of patients. There was a significant difference in the mean ADC values between endometrial carcinoma and normal endometrial parenchyma (1.39±0.27×10-3 versus 0.93±0.21×10-3 mm2/s, p<0.001). The mean ADC values of grade 1 patients were significantly higher than those of grade 3 patients (1.01±0.16×10-3 versus 0.83±0.21×10-3 mm2/s, p<0.05). The mean ADC values of stage IB patients were significantly lower than those of stage IA patients (0.86±0.16×10-3 versus 1.04±0.21×10-3 mm2/s, p<0.01). The mean ADC values of high Ki-67 expression patients were significantly lower than those of low Ki-67 expression patients (0.82±0.12×10-3 versus 1.16±0.12×10-3 mm2/s, p<0.001). There was a significant negative correlation between the mean ADC value and Ki-67 expression (r=-0.82, p<0.001).

CONCLUSION: The ADC value was a helpful parameter for detecting the tumour grade, stage, and proliferation of endometrial carcinoma, and may further improve patient prognosis and contribute to the development of more effective treatment programmes.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Jiang JX, Zhao JL, Zhang Q, et al. Endometrial carcinoma: diffusion-weighted imaging diagnostic accuracy and correlation with Ki-67 expression. Clin Radiol. 2017. PMID: 29246587. doi:10.1016/j.crad.2017.11.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。