文献速递妇产影像泌尿生殖技术与安全USMR

理解女性盆腔影像检查中的患者偏好:经阴道超声与磁共振成像

Understanding Patient Preference in Female Pelvic Imaging: Transvaginal Ultrasound and MRI.
PubMed 文献 · Acad Radiol · 2017-12-11

这项前瞻性研究纳入50例有盆腔症状的绝经前女性,用经验证问卷比较经阴道超声(TVUS)与磁共振成像(MRI)的检查体验。患者对TVUS的偏好略高于MRI(Wait Trade Off 3.58 vs 2.80周,95%CI -1.63, 0.12;P = .08),MRI的Testing Morbidities Index总效用差于TVUS(81.64 vs 87.42,95%CI 0.41, 11.15;P = .03)。识别每种检查的具体困扰方面及影响患者感知的因素,可指导检查环境和患者准备的改进。

要点

  • TVUS检查中患者报告的尴尬程度高于MRI(P <.0001)。
  • MRI检查前和检查中患者的恐惧与焦虑均高于TVUS(P <.0001和P <.001)。
  • MRI检查后患者的心理和躯体问题均多于TVUS(P = .02和P = .02)。

核心结论

  • 有盆腔症状的女性对TVUS的偏好略高于MRI但差异未达统计学显著(3.58 vs 2.80周,95%CI -1.63, 0.12;P = .08),MRI的Testing Morbidities Index总效用差于TVUS(81.64 vs 87.42,95%CI 0.41, 11.15;P = .03)。

研究设计与样本

  • 经机构审查委员会批准、符合《健康保险便携性与责任法案》的前瞻性研究,纳入50例有盆腔症状、近期接受过TVUS和MRI且无妇科癌症或子宫切除史的绝经前女性,采用电话问卷(含子宫肌瘤症状生活质量指数、Testing Morbidities Index和Wait Trade Off)。

诊断标准与关键数值

  • Wait Trade Off显示患者偏好TVUS高于MRI:TVUS 3.58周 vs MRI 2.80周,95%CI -1.63, 0.12;P = .08。
  • Testing Morbidities Index总效用MRI差于TVUS:MRI 81.64 vs TVUS 87.42,95%CI 0.41, 11.15;P = .03。
  • TVUS检查中尴尬程度高于MRI(P <.0001);MRI检查前恐惧与焦虑高于TVUS(P <.0001),检查中亦高于TVUS(P <.001)。
  • MRI检查后心理问题(P = .02)和躯体问题(P = .02)均多于TVUS。
  • 亚量表相关性:体力活动少的女性对TVUS评价更负面(R = -0.32,P = .03);健康失控症状更重(R = -0.28,P = .04)和性功能障碍更重(R = -0.30,P = .03)的女性对MRI评价更负面。

临床应用与阅片要点

  • 作者认为,识别每种检查的具体困扰方面及导致负面感知的患者因素,可指导检查环境和患者准备的改进。
  • 作者认为,改善患者体验可能提高影像检查的价值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Women with pelvic pain or abnormal uterine bleeding may undergo diagnostic imaging. This study evaluates patient experience in transvaginal ultrasound (TVUS) and magnetic resonance imaging (MRI) and explores correlations between preference and symptom severity.

MATERIALS AND METHODS: Institutional review board approval was obtained for this Health Insurance Portability and Accountability Act-compliant prospective study. Fifty premenopausal women with pelvic symptoms evaluated by recent TVUS and MRI and without history of gynecologic cancer or hysterectomy were included. A phone questionnaire used validated survey instruments including Uterine Fibroid Symptoms Quality of Life index, Testing Morbidities Index, and Wait Trade Off for TVUS and MRI examinations.

RESULTS: Using Wait Trade Off, patients preferred TVUS over MRI (3.58 vs 2.80 weeks, 95% confidence interval [CI] -1.63, 0.12; P = .08). Summary test utility of Testing Morbidities Index for MRI was worse than for TVUS (81.64 vs 87.42, 95%CI 0.41, 11.15; P = .03). Patients reported greater embarrassment during TVUS than during MRI (P <.0001), but greater fear and anxiety both before (P <.0001) and during (P <.001) MRI, and greater mental (P = .02) and physical (P = .02) problems after MRI versus TVUS. Subscale correlations showed physically inactive women rated TVUS more negatively (R = -0.32, P = .03), whereas women with more severe symptoms of loss of control of health (R = -0.28, P = .04) and sexual dysfunction (R = -0.30, P = .03) rated MRI more negatively.

CONCLUSION: Women with pelvic symptoms had a slight but significant preference for TVUS over MRI. Identifying specific distressing aspects of each test and patient factors contributing to negative perceptions can direct improvement in both test environment and patient preparation. Improved patient experience may increase imaging value.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Sakala MD, Carlos RC, Mendiratta-Lala M, et al. Understanding Patient Preference in Female Pelvic Imaging: Transvaginal Ultrasound and MRI. Acad Radiol. 2017. PMID: 29241597. doi:10.1016/j.acra.2017.10.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。