文献速递泌尿生殖儿科影像US

术前超声评估对单侧不可触及睾丸患者检出存活睾丸的影响

Impact of Preoperative Ultrasonographic Evaluation for Detection of a Viable Testis in Patients With a Unilateral Nonpalpable Testis.
PubMed 文献 · J Ultrasound Med · 2017-12-07

研究纳入单侧不可触及睾丸或单侧可触及隐睾患者,术前超声检查并按手术结果分为不可触及睾丸/无睾丸组(27例)、不可触及睾丸/存活睾丸组(10例)和可触及隐睾组(63例)。结果显示对侧降入睾丸体积在无睾丸组显著大于存活睾丸组和可触及隐睾组;以睾丸体积0.54 mL为阈值预测患侧睾丸存在的敏感度、特异度、阳性预测值和阴性预测值分别为75.3%、100%、100%和60.0%。结论认为术前超声通过评估未受累侧和患侧可为预测单侧不可触及睾丸患者是否存在存活睾丸提供有价值的信息。

要点

  • 不可触及睾丸/无睾丸组的对侧降入睾丸体积显著大于不可触及睾丸/存活睾丸组和可触及隐睾组。
  • 以睾丸体积0.54 mL为阈值预测患侧睾丸存在的敏感度75.3%、特异度100%、阳性预测值100%、阴性预测值60.0%。
  • 患侧可见睾丸且睾丸体积≤0.54 mL定义为阳性时,不可触及睾丸/存活睾丸组和可触及隐睾组全部阳性,无睾丸组无一阳性。

核心结论

  • 术前超声通过评估未受累侧和患侧睾丸,可为预测单侧不可触及睾丸患者是否存在存活睾丸提供有价值的信息。

研究设计与样本

  • 研究纳入单侧不可触及睾丸或单侧可触及隐睾且接受术前超声检查的患者,分为不可触及睾丸/无睾丸组(n=27)、不可触及睾丸/存活睾丸组(n=10)和可触及隐睾组(n=63),比较各组术前超声表现。

关键影像表现/征象

  • 不可触及睾丸/无睾丸组的对侧降入睾丸体积显著大于不可触及睾丸/存活睾丸组和可触及隐睾组。
  • 患侧睾丸在不可触及睾丸/无睾丸组中均未检出,在不可触及睾丸/存活睾丸组中检出7例,在可触及隐睾组中全部检出。

诊断标准与关键数值

  • 以睾丸体积0.54 mL为阈值预测患侧睾丸存在:敏感度75.3%、特异度100%、阳性预测值100%、阴性预测值60.0%。
  • 以患侧可见睾丸且睾丸体积≤0.54 mL为阳性标准:不可触及睾丸/存活睾丸组和可触及隐睾组全部阳性,不可触及睾丸/无睾丸组无一阳性。

临床应用与阅片要点

  • 术前超声可评估对侧降入睾丸体积及患侧睾丸情况,辅助预测单侧不可触及睾丸患者是否存在存活睾丸。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the impact of preoperative ultrasonography (US) for detecting a viable testis in patients with a unilateral nonpalpable testis.

METHODS: Patients with a unilateral nonpalpable testis or unilateral palpable undescended testis who underwent preoperative US were enrolled. Patients were divided into 3 groups as follows: nonpalpable testis/no testis (n = 27), which included patients who had a unilateral nonpalpable testis with no viable testis detected at surgery; nonpalpable testis/viable testis (n = 10), which included patients who had a unilateral nonpalpable testis with a viable testis identified at surgery; and palpable undescended testis (n = 63), which included patients who had a unilateral palpable undescended testis. Preoperative US findings were compared among each group.

RESULTS: The testicular volume on the contralateral descended side in the nonpalpable testis/no testis group was significantly greater than that in the nonpalpable testis/viable testis and palpable undescended testis groups. When a testicular volume of 0.54 mL was used as the cutoff value, the sensitivity, specificity, positive predictive value, and negative predictive value for the presence of the affected testis were 75.3%, 100%, 100%, and 60.0%, respectively. The testis on the affected side was detected in none of the nonpalpable testis/no testis group, 7 of the nonpalpable testis/viable testis group, and all of the palpable undescended testis group. When a visible testis on the affected side and a testicular volume of 0.54 mL or less were defined as positive, all patients in the nonpalpable testis/viable testis and palpable undescended testis groups had positive findings versus none in the nonpalpable testis/no testis group.

CONCLUSIONS: Preoperative US provides valuable information for predicting the presence of a viable testis in patients with a unilateral nonpalpable testis by estimating both the unaffected testis and the affected side.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Moriya K, Nakamura M, Nishimura Y, et al. Impact of Preoperative Ultrasonographic Evaluation for Detection of a Viable Testis in Patients With a Unilateral Nonpalpable Testis. J Ultrasound Med. 2017. PMID: 29214663. doi:10.1002/jum.14509

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。