前列腺外周带PI-RADS 4病变的特征:一项评估170个病变的回顾性诊断准确性研究
该回顾性诊断准确性研究纳入2015年8月1日至2016年12月31日前瞻性识别的外周带PI-RADS 4病变170个(149例mpMRI),由两名盲法泌尿生殖放射科医生独立评估PI-RADS v2形状、外周带保留模式及PI-RADS 4判定理由,以靶向MR-超声融合活检检出Gleason 7+前列腺癌为参考标准。DWI评分为4的PI-RADS 4病变更可能为Gleason 7+前列腺癌;被过度诊断为PI-RADS 4的病变PPV与已发表的PI-RADS 3数据相似;病变形状和外周带保留模式总体上不能预测Gleason 7+前列腺癌。
要点
- 外周带PI-RADS 4病变中,DWI评分为4者较DWI评分为3者更可能为Gleason 7+前列腺癌。
- 被判定为「不符合PI-RADS 4标准」的病变PPV显著更低(读者1为14%,读者2为16%)。
- 病变形状和外周带保留模式总体上不能预测PI-RADS 4病变中的Gleason 7+前列腺癌。
核心结论
- 外周带PI-RADS 4病变中,DWI评分为4者较DWI评分为3者更可能为Gleason 7+前列腺癌;被过度诊断为PI-RADS 4的病变PPV与已发表的PI-RADS 3数据相似;病变形状和外周带保留模式总体上不能预测PI-RADS 4病变中的Gleason 7+前列腺癌。
研究设计与样本
- IRB批准、符合HIPAA的回顾性诊断准确性研究,纳入2015年8月1日至2016年12月31日期间在研究机构前瞻性识别的外周带PI-RADS 4病变170个(来自149例mpMRI),由两名盲法泌尿生殖放射科医生独立评估PI-RADS v2形状、外周带保留模式及PI-RADS 4判定理由,参考标准为靶向MR-超声融合活检检出Gleason 7+前列腺癌,采用二元逻辑回归评估预测因素。
关键影像表现/征象
- PI-RADS 4病变中,DWI评分为4的病变更可能代表Gleason 7+前列腺癌(p=0.008-0.01;读者1 PPV为53%,读者2 PPV为48%)。
- 被评分为「不符合PI-RADS 4标准」的病变PPV显著更低(p=0.016-0.003;读者1 PPV为14%,读者2 PPV为16%)。
- 椭圆形病变对读者1有预测价值(PPV=59%,p=0.03),透镜形病变对读者2有预测价值(PPV=74%,p=0.01)。
诊断标准与关键数值
- DWI评分为4的PI-RADS 4病变:读者1 PPV 53%,读者2 PPV 48%,p=0.008-0.01。
- 被评分为「不符合PI-RADS 4标准」的病变:读者1 PPV 14%,读者2 PPV 16%,p=0.016-0.003。
- 椭圆形病变:读者1 PPV 59%,p=0.03。
- 透镜形病变:读者2 PPV 74%,p=0.01。
临床应用与阅片要点
- 在外周带PI-RADS 4病变中,可关注DWI评分是否为4,因其与Gleason 7+前列腺癌风险较高相关。
- 对判定为「不符合PI-RADS 4标准」的病变,需注意其PPV较低,与已发表的PI-RADS 3数据相似。
- 病变形状和外周带保留模式总体上未显示对Gleason 7+前列腺癌的预测价值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To determine whether peripheral zone PI-RADS 4 observations can be further risk-stratified.
METHODS: This was an IRB-approved HIPAA-compliant retrospective diagnostic accuracy study. Peripheral zone PI-RADS 4 observations prospectively identified at the study institution from 8/1/2015 to 12/31/2016 (n = 170 in 149 mpMRIs) were reviewed independently by two blinded genitourinary radiologists on the basis of (a) PI-RADS v2 shape, (b) pattern of peripheral zone sparing, and (c) rationale for PI-RADS 4 designation. Reference standard was targeted MR-ultrasound fusion biopsy and detection of Gleason 7+ prostate cancer. Positive predictive values (PPVs) were calculated. Predictors were assessed with binary logistic regression.
RESULTS: PI-RADS 4 lesions with a DWI score of 4 were more likely to represent Gleason 7+ prostate cancer (p = 0.008-0.01; Reader 1 PPV: 53%; Reader 2 PPV: 48%). Pattern of peripheral zone sparing and most lesion shapes were not predictive (p > 0.05); however, oval lesions were predictive for Reader 1 (PPV = 59%, p = 0.03) and lentiform lesions were predictive for Reader 2 (PPV = 74%, p = 0.01). Lesions scored as "not meeting PI-RADS 4 criteria" had significantly lower PPV (p = 0.016-0.003; Reader 1 PPV: 14%, Reader 2 PPV: 16%).
DISCUSSION: Peripheral zone PI-RADS 4 lesions with a DWI score of 4 are more likely Gleason 7+ cancer than those with a DWI score of 3. Lesions overcalled as PI-RADS 4 have PPV similar to published PI-RADS 3 data. Lesion shape and peripheral zone sparing in general do not predict Gleason 7+ cancer within PI-RADS 4 observations.
引用
- Shankar PR, Curci NE, Davenport MS, et al. Characteristics of PI-RADS 4 lesions within the prostatic peripheral zone: a retrospective diagnostic accuracy study evaluating 170 lesions. Abdom Radiol (NY). 2018. PMID: 29198006. doi:10.1007/s00261-017-1415-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。