文献速递泌尿生殖腹部MR

双参数MRI纹理分析在区域特异性区域检测和评估高级别前列腺癌的临床应用

Clinical Application of Biparametric MRI Texture Analysis for Detection and Evaluation of High-Grade Prostate Cancer in Zone-Specific Regions.
PubMed 文献 · AJR Am J Roentgenol · 2017-12-08

回顾性纳入184例连续登记的可疑前列腺癌且未活检患者,行多参数前列腺MRI,两位阅片者分别用PI-RADSv2和双参数MRI纹理分析评分。纹理分析模型诊断性能优于PI-RADSv2(移行区AUC 0.87,外周区AUC 0.89),移行区熵与外周区熵、惯性均与高级别前列腺癌Gleason评分呈中至高度相关。

要点

  • 双参数MRI纹理分析模型诊断高级别前列腺癌的AUC在移行区为0.87、外周区为0.89,优于PI-RADSv2。
  • 移行区熵与Gleason评分相关(r=0.562,p=0.004),外周区熵(r=0.614,p=0.003)和惯性(r=0.663,p=0.002)与Gleason评分相关。
  • PI-RADSv2读者间信度中等至好(Cohen κ=0.525-0.616),纹理参数信度好至优(ICC 0.745-0.925)。

核心结论

  • 基于双参数MRI的纹理分析模型可用于识别高级别前列腺癌,纹理分析提取的特定参数可能成为评估肿瘤侵袭性的附加工具。

研究设计与样本

  • 回顾性研究,纳入184例连续登记的可疑前列腺癌且未活检患者,行多参数前列腺MRI;两位阅片者分别使用PI-RADSv2和双参数MRI纹理分析独立评分;按前列腺不同区域建立基于纹理分析的逻辑回归模型,用ROC分析比较纹理分析模型与其他单独参数。

诊断标准与关键数值

  • 纹理分析模型诊断高级别前列腺癌的AUC:移行区0.87,外周区0.89,优于PI-RADSv2和其他单独纹理参数;移行区熵与Gleason评分相关(r=0.562,p=0.004),外周区熵(r=0.614,p=0.003)和惯性(r=0.663,p=0.002)与Gleason评分相关;PI-RADSv2读者间信度Cohen κ=0.525-0.616,纹理参数读者间信度ICC 0.745-0.925。

临床应用与阅片要点

  • 作者指出基于双参数MRI的纹理分析模型可用于识别高级别前列腺癌,纹理分析提取的特定参数可能作为评估肿瘤侵袭性的附加工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study was to investigate the performance of biparametric MRI texture analysis (TA) in detecting and evaluating high-grade prostate cancer in zone-specific regions.

MATERIALS AND METHODS: A retrospective study included 184 consecutively registered biopsy-naive patients in whom prostate cancer was suspected who were undergoing multiparametric prostate MRI. MR images were scored and evaluated by two readers using the Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) and biparametric MRI TA in separate sessions. Interobserver agreement on PI-RADSv2 score and textural parameters of biparametric MRI was evaluated. The logistic regression model based on TA was built for different zones of the prostate. ROC analysis was used to compare the TA-based model with other parameters alone. The correlation of each parameter with Gleason score of high-grade prostate cancer was also assessed.

RESULTS: Reader reliability ranged from moderate to good for PI-RADSv2 (Cohen κ = 0.525-0.616) and from good to excellent for textural metrics (intraclass correlation coefficient, 0.745-0.925). Diagnostic performance was significantly improved by use of the TA-based model (transition zone AUC, 0.87; peripheral zone AUC, 0.89) in comparison with PI-RADSv2 and other texture parameters alone. For the transition zone, entropy had moderate to good correlation with the Gleason score of high-grade prostate cancer (r = 0.562, p = 0.004). In the peripheral zone, entropy (r = 0.614, p = 0.003) and inertia (r = 0.663, p = 0.002) had moderate to good correlations with Gleason score.

CONCLUSION: The results of this clinical study indicate that a TA-based model that includes biparametric MRI can be used for identifying high-grade prostate cancer and that specific parameters extracted from TA may be additional tools for assessing tumor aggressiveness.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。