文献速递泌尿生殖MRUS

超声造影与动态增强磁共振成像在前列腺癌检出及侵袭性预测中的直接比较

A direct comparison of contrast-enhanced ultrasound and dynamic contrast-enhanced magnetic resonance imaging for prostate cancer detection and prediction of aggressiveness.
PubMed 文献 · Eur Radiol · 2017-12-13

该研究对92例患者进行事后分析,比较超声造影(CEUS)与动态增强磁共振成像(DCE-MRI)在前列腺癌检出及侵袭性预测中的价值,以靶向穿刺活检为参考标准。结果显示,DCE-MRI在检出前列腺癌及预测侵袭性方面表现更优,两种技术在周围带病灶中的表现均优于移行带病灶。

要点

  • DCE-MRI参数Kep在全前列腺和高危前列腺癌鉴别中AUC分别为0.83和0.89,表现优于CEUS。
  • CEUS参数中仅达峰时间在周围带病灶中可区分良恶性(AUC 0.65)。
  • 两种影像技术对周围带病灶的评估均优于移行带病灶。

核心结论

  • DCE-MRI在检出前列腺癌及预测其侵袭性方面表现优于CEUS;CEUS与DCE-MRI在周围带病灶中的表现均优于移行带病灶。

研究设计与样本

  • 对92例患者进行事后分析,分析每例患者MRI上最可疑病灶的CEUS与DCE-MRI参数,以靶向穿刺活检为参考标准(良性病变n=51,低/中级别前列腺癌[Gleason分级组1和2]n=22,高级别前列腺癌[≥Gleason分级组3]n=19)。

诊断标准与关键数值

  • 在周围带病灶中,CEUS参数仅达峰时间(TTPCEUS)在良性病变与前列腺癌间显示显著差异(AUC 0.65);DCE-MRI参数中速率常数(Kep)在全前列腺鉴别高级别前列腺癌的AUC为0.83,在周围带病灶中AUC为0.89。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: Dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and contrast-enhanced ultrasound (CEUS) analyse tissue vascularization. We evaluated if CEUS can provide comparable information as DCE-MRI for the detection of prostate cancer (PCa) and prediction of its aggressiveness.

MATERIAL AND METHODS: A post-hoc evaluation of 92 patients was performed. In each patient CEUS and DCE-MRI parameters of the most suspicious lesion identified on MRI were analysed. The predictive values for discrimination between benign lesions, low-/intermediate- and high-grade PCa were evaluated. Results of targeted biopsy served as reference standard (benign lesions, n=51; low- and intermediate-grade PCa [Gleason grade group 1 and 2], n=22; high-grade PCa [≥ Gleason grade group 3], n=19).

RESULTS: In peripheral zone lesions of all tested CEUS parameters only time to peak (TTPCEUS) showed significant differences between benign lesions and PCa (AUC 0.65). Of all tested DCE-MRI parameters, rate constant (Kep) was the best discriminator of high-grade PCa in the whole prostate (AUC 0.83) and in peripheral zone lesions (AUC 0.89).

CONCLUSION: DCE-MRI showed a superior performance for detection of PCa and prediction of its aggressiveness. CEUS and DCE-MRI performed better in peripheral zone lesions than in transition zone lesions.

KEY POINTS: • DCE-MRI gathers information about vascularization and capillary permeability characteristics of tissues. • DCE-MRI can detect PCa and predict its aggressiveness. • CEUS also gathers information about vascularization of tissues. • For detection of PCa and prediction of aggressiveness DCE-MRI performed superiorly. • Both imaging techniques performed better in peripheral zone lesions.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Baur ADJ, Schwabe J, Rogasch J, et al. A direct comparison of contrast-enhanced ultrasound and dynamic contrast-enhanced magnetic resonance imaging for prostate cancer detection and prediction of aggressiveness. Eur Radiol. 2017. PMID: 29238867. doi:10.1007/s00330-017-5192-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。