文献速递腹部MR

使用定量扩散加权MRI预测肝细胞癌组织学分级:一项回顾性多厂商研究

Prediction of histological grade of hepatocellular carcinoma using quantitative diffusion-weighted MRI: a retrospective multivendor study.
PubMed 文献 · Br J Radiol · 2018-02-05

该回顾性多厂商研究纳入6家机构83例患者共100个经组织学诊断的肝细胞癌,评估术前肝脏扩散加权成像(b=0和1000或b=0和800 s mm⁻²)的定量参数预测肝细胞癌分级的作用。两位放射科医师独立测量病灶的表观扩散系数(ADC)及非ADC参数(相对对比度和对比噪声比),并用ROC分析比较各参数鉴别低分化肝细胞癌的诊断性能。结果显示所有扩散加权参数均可区分肝细胞癌分级,非ADC参数可能比ADC更有用于预测低分化肝细胞癌。

要点

  • 所有扩散加权参数均可区分肝细胞癌组织学分级
  • 非ADC参数可能比ADC更有用于预测低分化肝细胞癌
  • b=1000 s mm⁻²时CNR与ADC的AUC差异有统计学意义(p<0.05),其余参数间差异不显著

核心结论

  • 所有扩散加权参数均可区分肝细胞癌分级,非ADC参数可能比ADC更有用于预测低分化肝细胞癌。

研究设计与样本

  • 回顾性多厂商研究,纳入6家机构83例患者共100个经组织学诊断的肝细胞癌,术前肝脏扩散加权成像采用b=0和1000 s mm⁻²或b=0和800 s mm⁻²,由两位放射科医师独立测量ADC及非ADC参数(相对对比度、对比噪声比),以组织学分级为参考标准。

诊断标准与关键数值

  • 鉴别低分化肝细胞癌的ROC曲线下面积:b=1000 s mm⁻²时CNR为86.4%(95%CI 77.2-95.6),b=800 s mm⁻²时CNR为83.9%(95%CI 71.2-96.6);b=1000 s mm⁻²时相对对比度为85.3%(95%CI 75.5-94.8),b=800 s mm⁻²时相对对比度为83.5%(95%CI 70.5-96.4);b=1000 s mm⁻²时ADC为71.1%(95%CI 56.9-85.2),b=800 s mm⁻²时ADC为75.7%(95%CI 55.1-96.2);b=1000 s mm⁻²时CNR与ADC的AUC差异有统计学意义(p<0.05),其余参数间差异不显著。

临床应用与阅片要点

  • 作者认为非ADC参数(相对对比度、对比噪声比)可能比ADC更有用于预测低分化肝细胞癌;上述参数来自多厂商磁共振设备,可用于术前扩散加权成像评估肝细胞癌分级。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the usefulness of quantitative diffusion-weighted (DW) imaging acquired by multivendor magnetic resonance units for predicting grade of hepatocellular carcinoma (HCC).

METHODS: 83 patients with 100 histologically diagnosed HCCs who underwent pre-operative liver DW imaging with b = 0 and1000 s mm-2 or b = 0 and800 s mm-2 at any of six institutions were included. Two radiologists independently measured the apparent diffusion coefficient (ADC) of the lesion as well as non-ADC parameters, such as the relative contrast ratio and the contrast-to-noise ratio (CNR) between the lesion and the liver parenchyma on high b-value DW images. The diagnostic performance of the DW parameters in discriminating poorly-differentiated HCCs was compared using receiver operating characteristic (ROC) analysis.

RESULTS: The areas under the receiver operating characteristic curves for the CNR (86.4% [95% confidence interval (CI) (77.2-95.6] and 83.9% [95% CI 71.2-96.6] for b = 1000 and 800 s mm-2, respectively] and the relative contrast ratio (85.3% [95% CI 75.5-94.8] and 83.5% [95% CI 70.5-96.4]) tended to be superior to the ADC [71.1% [95% CI (56.9-85.2)] and 75.7% [95% CI (55.1-96.2)]; p < 0.05 for CNR vs ADC for b = 1000 s mm-2, but not significant for other parameters) for discrimination of poorly-differentiated HCCs.

CONCLUSION: All DW parameters could discriminate HCC grade. Non-ADC parameters might be more useful than the ADC for predicting poorly-differentiated HCCs. Advances in knowledge: The utility of quantitative DW parameters for predicting HCC grade was demonstrated by using multivendor MR units.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Ogihara Y, Kitazume Y, Iwasa Y, et al. Prediction of histological grade of hepatocellular carcinoma using quantitative diffusion-weighted MRI: a retrospective multivendor study. Br J Radiol. 2018. PMID: 29271235. doi:10.1259/bjr.20170728

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。