迭代重建CT图像中定量测量与受试者工作特征曲线及视觉分级回归的比较:体模研究

Quantitative Measurements Versus Receiver Operating Characteristics and Visual Grading Regression in CT Images Reconstructed with Iterative Reconstruction: A Phantom Study.
PubMed 文献 · Acad Radiol · 2017-11-29

该体模研究在GE、Philips和Toshiba CT扫描仪上以三种剂量水平扫描肝脏体模,比较迭代重建与滤波反投影的定量测量、ROC和视觉分级回归结果,发现定量指标改善并不等同于诊断准确性提高。

要点

  • 迭代重建较FBP改善定量噪声指标,但不等于诊断准确性提高。
  • ASiR和AIDR提高病灶检测,iDose降低病灶检测。
  • VGR显示iDose和AIDR增加锐利度,AIDR减少脊柱伪影。

核心结论

  • 迭代重建图像较FBP改善的定量测量结果并不等同于诊断图像准确性的提高。

研究设计与样本

  • 体模研究,在GE、Philips和Toshiba CT扫描仪上以三种剂量水平扫描肝脏体模,采用FBP和不同强度的混合迭代技术重建,由五名读者进行视觉评估。

关键影像表现/征象

  • VGR发现所有算法噪声特性改善。
  • VGR发现iDose和AIDR锐利度增加。
  • VGR发现AIDR减少脊柱伪影,而iDose增加脊柱伪影。
  • ASiR和iDose降低脊柱对比度。

诊断标准与关键数值

  • ROC分析显示ASiR和AIDR病灶检测改善,iDose病灶检测降低。
  • 视觉评估采用四级和五级序数标度,针对肝脏低对比病灶和10项图像质量标准。
  • 定量测量包括标准差、信噪比和对比噪声比。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: This study aimed to evaluate the correlation of quantitative measurements with visual grading regression (VGR) and receiver operating characteristics (ROC) analysis in computed tomography (CT) images reconstructed with iterative reconstruction.

MATERIALS AND METHODS: CT scans on a liver phantom were performed on CT scanners from GE, Philips, and Toshiba at three dose levels. Images were reconstructed with filtered back projection (FBP) and hybrid iterative techniques (ASiR, iDose, and AIDR 3D of different strengths). Images were visually assessed by five readers using a four- and five-grade ordinal scale for liver low contrast lesions and for 10 image quality criteria. The results were analyzed with ROC and VGR. Standard deviation, signal-to-noise ratios, and contrast-to-noise ratios were measured in the images.

RESULTS: All data were compared to FBP. The results of the quantitative measurements were improved for all algorithms. ROC analysis showed improved lesion detection with ASiR and AIDR and decreased lesion detection with iDose. VGR found improved noise properties for all algorithms, increased sharpness with iDose and AIDR, and decreased artifacts from the spine with AIDR, whereas iDose increased the artifacts from the spine. The contrast in the spine decreased with ASiR and iDose.

CONCLUSIONS: Improved quantitative measurements in images reconstructed with iterative reconstruction compared to FBP are not equivalent to improved diagnostic image accuracy.

来源:Acad Radiol,查看原文。版权归原作者所有。