文献速递腹部MR

3.0T下钆塞酸二钠增强肝脏CAIPIRINHA-Dixon-TWIST(CDT)-VIBE磁共振成像:能否解决瞬时动脉期呼吸运动相关伪影?

CAIPIRINHA-Dixon-TWIST (CDT)-VIBE MR imaging of the liver at 3.0T with gadoxetate disodium: a solution for transient arterial-phase respiratory motion-related artifacts?
PubMed 文献 · Eur Radiol · 2017-12-20

回顾性纳入270例接受钆塞酸二钠肝脏MRI检查的患者,比较VIBE、CAIPIRINHA-VIBE与CDT-VIBE各90例的动脉期时序准确性和运动伪影严重程度。CDT-VIBE的晚期动脉期成功显示率为84.4%,高于VIBE的56.7%和CAIPIRINHA-VIBE的66.7%(P<0.0001);良好/优秀图像质量率分别为73.3%、56.7%和66.7%(P=0.03)。结论认为CDT-VIBE通过减少呼吸运动伪影和优化晚期动脉期显示,提高了钆塞酸二钠肝脏MRI的诊断效用。

要点

  • CDT-VIBE晚期动脉期成功显示率84.4%,高于VIBE的56.7%和CAIPIRINHA-VIBE的66.7%(P<0.0001)。
  • 良好/优秀图像质量率CDT-VIBE为73.3%,VIBE为56.7%,CAIPIRINHA-VIBE为66.7%(P=0.03)。
  • 男性性别对图像质量有负面影响(P=0.03)。

核心结论

  • CDT-VIBE通过减少呼吸运动伪影并优化晚期动脉期显示,较VIBE和CAIPIRINHA-VIBE提高了钆塞酸二钠肝脏MRI的诊断效用。

研究设计与样本

  • 回顾性评估270例接受钆塞酸二钠肝脏MRI检查的患者,VIBE、CAIPIRINHA-VIBE和CDT-VIBE各90例,由三名独立且盲法的阅片者评估动脉期时序和运动伪影严重程度(5分制)。

关键影像表现/征象

  • CDT-VIBE提高了正确的晚期动脉期时序率并降低了运动相关图像劣化率。
  • 晚期动脉期肝脏成功显示率:VIBE为56.7%,CAIPIRINHA-VIBE为66.7%,CDT-VIBE为84.4%(P<0.0001)。
  • 良好/优秀图像质量率:VIBE为56.7%,CAIPIRINHA-VIBE为66.7%,CDT-VIBE为73.3%(P=0.03)。
  • 男性性别对图像质量有负面影响(P=0.03)。

诊断标准与关键数值

  • 动脉期运动伪影严重程度采用5分制评估。
  • 晚期动脉期肝脏成功显示率:VIBE为56.7%,CAIPIRINHA-VIBE为66.7%,CDT-VIBE为84.4%(P<0.0001)。
  • 良好/优秀图像质量率:VIBE为56.7%,CAIPIRINHA-VIBE为66.7%,CDT-VIBE为73.3%(P=0.03)。

临床应用与阅片要点

  • CDT-VIBE可减少钆塞酸二钠引起的急性短暂性呼吸困难所致运动伪影对动脉期图像的影响。
  • 与VIBE和CAIPIRINHA-VIBE相比,CDT-VIBE提高了理想晚期动脉期图像的比例。
  • 男性性别与图像质量负相关(P=0.03),阅片时需考虑。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine whether CAIPIRINHA-Dixon-TWIST (CDT) volume-interpolated breath-hold examination (VIBE) improves image quality by reducing gadoxetate-disodium-associated transient arterial-phase motion artefacts in magnetic resonance imaging (MRI) of the liver.

MATERIALS AND METHODS: MRI studies of the liver from 270 patients who had received gadoxetate disodium were retrospectively evaluated in regard to arterial timing accuracy and arterial phase motion artefact severity (VIBE: 90/270, CAIPIRINHA-VIBE: 90/270 and CDT-VIBE: 90/270 cases). Three independent and blinded readers assessed arterial phase timing and motion artefact severity (5-point scale). Interrater agreement was calculated by weighted kappa. Continuous variables were compared via a two-sided ANOVA, categorical variables via a χ2 test. An ordinal regression analysis was performed to identify other predictors of motion artefacts.

RESULTS: CDT-VIBE improved correct late arterial timing rates and reduced motion-related image deterioration rates. Successful late arterial liver visualisation was achieved in 56.7% (VIBE) compared with 66.7% (CAIPIRINHA-VIBE) and 84.4% (CDT-VIBE) (P < 0.0001). Good/excellent image quality was achieved in 56.7% vs. 66.7% and 73.3%, respectively (P = 0.03). Male sex negatively influenced image quality (P = 0.03).

CONCLUSION: CDT-VIBE increases the diagnostic utility of gadoxetate disodium-based liver MRI by reducing respiratory motion artefacts and optimising late arterial visualisation compared with VIBE and CAIPIRINHA-VIBE.

KEY POINTS: • CAIPIRINHA-Dixon-TWIST-VIBE-MRI (CDT) mitigates effects of acute transient dyspnoea caused by gadoxetate disodium. • CDT improves late arterial imaging compared with VIBE and CAIPIRINHA-VIBE. • The rate of ideal late arterial images is higher with CDT-VIBE vs. VIBE or CAIPI-VIBE. • The impact of respiratory motion artefacts on arterial phase images can be reduced.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Gruber L, Rainer V, Plaikner M, et al. CAIPIRINHA-Dixon-TWIST (CDT)-VIBE MR imaging of the liver at 3.0T with gadoxetate disodium: a solution for transient arterial-phase respiratory motion-related artifacts? Eur Radiol. 2017. PMID: 29264636. doi:10.1007/s00330-017-5210-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。