自由呼吸动态增强MRI采用黄金角径向堆叠星VIBE序列用于胃癌的可行性:与传统屏气增强3D VIBE序列比较
研究43例胃癌患者分配合与不配合组,比较自由呼吸黄金角径向堆叠星3D GRE序列与传统屏气VIBE序列的DCE-MRI图像质量和定量参数。不配合组3D GRE定性评分更高、SNR和CNR更高;配合组3D GRE定性评分较低但伪影更少。胃癌病灶较正常胃壁Ve更高、Kep更低。
要点
- 不配合患者中3D GRE序列定性评分、SNR和CNR均高于传统VIBE。
- 配合患者中3D GRE定性评分低于VIBE,但伪影更少。
- 胃癌病灶较正常胃壁Ve更高、Kep更低。
核心结论
- 自由呼吸黄金角径向堆叠星3D GRE技术用于胃癌DCE-MRI可行,动态增强图像可用于该恶性肿瘤的定量分析。
研究设计与样本
- 43例胃癌患者分为配合组(屏气超过15秒)和不配合组,采用3-T MRI扫描方案,包括3D GRE和传统屏气VIBE序列,对图像进行定量和定性比较,并比较正常胃壁与恶性病灶的DCE-MRI参数。
关键影像表现/征象
- 不配合患者中3D GRE定性评分更高,SNR和CNR均高于传统VIBE。
- 配合患者中3D GRE定性参数评分低于传统VIBE,但图像伪影更少。
- 胃癌病灶与正常胃壁的DCE参数差异显著,胃癌Ve更高、Kep更低。
诊断标准与关键数值
- 胃癌病灶较正常胃壁Ve更高、Kep更低。
临床应用与阅片要点
- 3D GRE技术适用于无法屏气的患者。
- 动态增强图像可用于胃癌的定量分析。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the feasibility and diagnostic value of free-breathing, radial, stack-of-stars three-dimensional (3D) gradient echo (GRE) sequence ("golden angle") on dynamic contrast-enhanced (DCE) MRI of gastric cancer.
METHODS: Forty-three gastric cancer patients were divided into cooperative and uncooperative groups. Respiratory fluctuation was observed using an abdominal respiratory gating sensor. Those who breath-held for more than 15 s were placed in the cooperative group and the remainder in the uncooperative group. The 3-T MRI scanning protocol included 3D GRE and conventional breath-hold VIBE (volume-interpolated breath-hold examination) sequences, comparing images quantitatively and qualitatively. DCE-MRI parameters from VIBE images of normal gastric wall and malignant lesions were compared.
RESULTS: For uncooperative patients, 3D GRE scored higher qualitatively, and had higher SNRs (signal-to-noise ratios) and CNRs (contrast-to-noise ratios) than conventional VIBE quantitatively. Though 3D GRE images scored lower in qualitative parameters compared with conventional VIBE for cooperative patients, it provided images with fewer artefacts. DCE parameters differed significantly between normal gastric wall and lesions, with higher Ve (extracellular volume) and lower Kep (reflux constant) in gastric cancer.
CONCLUSIONS: The free-breathing, golden-angle, radial stack-of-stars 3D GRE technique is feasible for DCE-MRI of gastric cancer. Dynamic enhanced images can be used for quantitative analysis of this malignancy.
KEY POINTS: • Golden-angle radial stack-of-stars VIBE aids gastric cancer MRI diagnosis. • The 3D GRE technique is suitable for patients unable to suspend respiration. • Method scored higher in the qualitative evaluation for uncooperative patients. • The technique produced images with fewer artefacts than conventional VIBE sequence. • Dynamic enhanced images can be used for quantitative analysis of gastric cancer.
引用
- Li HH, Zhu H, Yue L, et al. Feasibility of free-breathing dynamic contrast-enhanced MRI of gastric cancer using a golden-angle radial stack-of-stars VIBE sequence: comparison with the conventional contrast-enhanced breath-hold 3D VIBE sequence. Eur Radiol. 2017. PMID: 29260366. doi:10.1007/s00330-017-5193-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。