以生化提取和病理为参考验证QCT和CSE-MRI测量鹅肝脂肪
研究收集22只肝脏脂肪变性范围较广的鹅,行QCT和CSE-MRI检查后取肝左叶及右叶上、下半样本行生化测定与组织学检查。QCT肝脂肪百分比和MRI-PDFF均与化学提取法高度相关(r=0.922和r=0.949,均p<0.001),提示两种方法测量鹅肝脂肪准确可靠。
要点
- QCT肝脂肪百分比与化学提取法高度相关(r=0.922,p<0.001)。
- MRI-PDFF与化学提取法高度相关(r=0.949,p<0.001)。
- 组织学分级评估肝脂肪变性存在较大的采样变异性。
核心结论
- 与生化测定相比,QCT和CSE-MRI测量鹅肝脂肪准确且可靠。
- QCT和CSE-MRI在临床场景中具有潜力。
研究设计与样本
- 研究类型为验证性研究,收集22只肝脏脂肪变性范围较广的鹅。
- 每只鹅行QCT和CSE-MRI检查后取肝,于左叶及右叶上、下半取样行生化测定和组织学检查。
- 以生化测定为金标准,采用Spearman相关系数(r)和Passing-Bablok回归方程评估QCT与MRI测量的准确性。
诊断标准与关键数值
- QCT肝脂肪百分比与化学提取法高度相关,r=0.922(p<0.001)。
- MRI-PDFF与化学提取法高度相关,r=0.949(p<0.001)。
- 化学提取法测得的甘油三酯可由QCT肝脂肪百分比准确预测:Y=0.6+0.866×X。
- 化学提取法测得的甘油三酯可由MRI-PDFF准确预测:Y=-1.8+0.773×X。
临床应用与阅片要点
- QCT和CSE-MRI可用于测量肝脏脂肪含量,与生化测定结果一致。
- 组织学分级评估肝脂肪变性时采样变异性较大。
局限性
- 组织学分级评估肝脂肪变性存在较大的采样变异性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to validate the accuracy and reliability of quantitative computed tomography (QCT) and chemical shift encoded magnetic resonance imaging (CSE-MRI) to assess hepatic steatosis.
METHODS: Twenty-two geese with a wide range of hepatic steatosis were collected. After QCT and CSE-MRI examinations, the liver of each goose was removed and samples were taken from the left lobe, upper and lower half of the right lobe for biochemical measurement and histology. Fat percentages by QCT and proton density fat fraction by MRI (MRI-PDFF) were measured within the sample regions of biochemical measurement and histology. The accuracy of QCT and MR measurements were assessed through Spearman correlation coefficients (r) and Passing and Bablok regression equations using biochemical measurement as the "gold standard".
RESULTS: Both QCT and MRI correlated highly with chemical extraction [r = 0.922 (p < 0.001) and r = 0.949 (p < 0.001) respectively]. Chemically extracted triglyceride was accurately predicted by both QCT liver fat percentages (Y = 0.6 + 0.866 × X) and by MRI-PDFF (Y = -1.8 + 0.773 × X).
CONCLUSIONS: QCT and CSE-MRI measurements of goose liver fat were accurate and reliable compared with biochemical measurement.
KEY POINTS: • QCT and CSE-MRI can measure liver fat content accurately and reliably • Histological grading of hepatic steatosis has larger sampling variability • QCT and CSE-MRI have potential in the clinical setting.
引用
- Xu L, Duanmu Y, Blake GM, et al. Validation of goose liver fat measurement by QCT and CSE-MRI with biochemical extraction and pathology as reference. Eur Radiol. 2017. PMID: 29238866. doi:10.1007/s00330-017-5189-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。