文献速递腹部MR

单次屏气三维混合轮廓顺序技术三维T2加权快速自旋回波序列:在小肝病变诊断中的实用性

3D hybrid profile order technique in a single breath-hold 3D T2-weighted fast spin-echo sequence: Usefulness in diagnosis of small liver lesions.
PubMed 文献 · Eur J Radiol · 2017-11-20

本研究比较了单次屏气三维混合轮廓顺序各向同性T2加权快速自旋回波(3D-Hybrid BH)与二维T2加权快速自旋回波常规呼吸门控(2D-Conventional RG)显示小肝病变的效能。50例小(≤15mm)肝细胞癌(n=26)或良性囊肿(n=24)患者行肝脏MRI。3D-Hybrid BH采集时间缩短89%,SNR无显著差异,TLC的AUC显著更高,诊断效能显著改善且未牺牲准确性。

要点

  • 3D-Hybrid BH较2D-Conventional RG采集时间缩短89%,SNR无显著差异。
  • 3D-Hybrid BH的肿瘤-肝脏对比(TLC)AUC显著高于2D-Conventional RG。
  • 3D-Hybrid BH在小肝病变(≤15mm)诊断中显著改善诊断效能且未牺牲准确性。

核心结论

  • 3D-Hybrid BH序列显著改善小肝病变的诊断效能,采集时间更短且未牺牲准确性。

研究设计与样本

  • 经机构审查委员会批准、免除书面知情同意的研究,纳入50例小(≤15mm)肝细胞癌(n=26)或良性囊肿(n=24)患者,行肝脏MRI包括2D-Conventional RG和3D-Hybrid BH两种方案,计算SNR和TLC并分析诊断效能。

诊断标准与关键数值

  • 3D-Hybrid BH较2D-Conventional RG图像采集时间缩短89%。
  • 两种方案间SNR无显著差异。
  • 3D-Hybrid BH的TLC的AUC显著高于2D-Conventional RG。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: We compared the efficacy of three-dimensional (3D) isotropic T2-weighted fast spin-echo imaging using a 3D hybrid profile order technique with a single-breath-hold (3D-Hybrid BH) with a two-dimensional (2D) T2-weighted fast spin-echo conventional respiratory-gated (2D-Conventional RG) technique for visualising small liver lesions.

MATERIALS AND METHODS: This study was approved by our institutional review board. The requirement to obtain written informed consent was waived. Fifty patients with small (≤15mm) hepatocellular carcinomas (HCC) (n=26), or benign cysts (n=24), had undergone hepatic MRI including both 2D-Conventional RG and 3D-Hybrid BH. We calculated the signal-to-noise ratio (SNR) and tumour-to-liver contrast (TLC). The diagnostic performance of the two protocols was analysed.

RESULTS: The image acquisition time was 89% shorter with the 3D-Hybrid BH than with 2D-Conventional RG. There was no significant difference in the SNR between the two protocols. The area under the curve (AUC) of the TLC was significantly higher on 3D-Hybrid BH than on 2D-Conventional RG.

CONCLUSION: The 3D-Hybrid BH sequence significantly improved diagnostic performance for small liver lesions with a shorter image acquisition time without sacrificing accuracy.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Hirata K, Nakaura T, Okuaki T, et al. 3D hybrid profile order technique in a single breath-hold 3D T2-weighted fast spin-echo sequence: Usefulness in diagnosis of small liver lesions. Eur J Radiol. 2017. PMID: 29279148. doi:10.1016/j.ejrad.2017.11.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。