文献速递腹部介入US

腔内超声造影在术后胃肠道瘘管理中的应用

Intracavitary Contrast-Enhanced Ultrasound in the Management of Post-Surgical Gastrointestinal Fistulas.
PubMed 文献 · Ultrasound Med Biol · 2017-12-08

回顾性分析42例术后怀疑胃肠道吻合口瘘或超声发现积液伴腹痛发热的患者,经引流管注入超声造影剂行腔内超声造影。常规超声均未检出瘘,腔内超声造影检出16例、漏诊6例、误诊1例,敏感度72.7%、特异度95.0%、准确率83.3%,并用于指导引流和随访拔管。

要点

  • 常规超声对术后胃肠道瘘均未检出,腔内超声造影可提高诊断能力。
  • 腔内超声造影诊断胃肠道瘘的敏感度72.7%、特异度95.0%、准确率83.3%。
  • 根据造影剂分布可判断腹腔积液是否与瘘相关,并指导额外引流和随访拔管。

核心结论

  • 腔内超声造影可明显提高术后胃肠道瘘的诊断能力,并可能在介入治疗和随访中发挥重要作用。

研究设计与样本

  • 回顾性分析2010年6月至2016年8月收治的42例术后怀疑胃肠道吻合口瘘或超声发现积液伴腹痛发热的患者,经引流管注入超声造影剂行腔内超声造影,以标准参考方法确认瘘。

关键影像表现/征象

  • 常规超声未检出任何胃肠道瘘。
  • 腔内超声造影成功检出16例胃肠道瘘,漏诊6例,误诊1例。
  • 腔内超声造影根据造影剂分布判断14例患者的20个腹腔积液与瘘相关。

诊断标准与关键数值

  • 腔内超声造影诊断胃肠道瘘的敏感度为72.7%(16/22),特异度为95.0%(19/20)。
  • 阳性预测值为94.1%(16/17),阴性预测值为76.0%(19/25),准确率为83.3%(35/42)。

临床应用与阅片要点

  • 对术后怀疑胃肠道瘘或超声发现积液伴腹痛发热的患者,可经引流管注入超声造影剂行腔内超声造影评估。
  • 根据造影剂分布判断腹腔积液是否与瘘相关,14个瘘相关积液进行了额外引流。
  • 腔内超声造影复查判断8例胃肠道瘘治愈后拔除引流管。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The goal of this study was to investigate intracavitary contrast-enhanced ultrasound (IC-CEUS) measures in the management of post-surgical gastrointestinal (GI) fistula throughout detection, treatment and follow-up. From June 2010 to August 2016, patients who were administered ultrasound contrast agent (UCA) via a drainage tube for IC-CEUS were enrolled and retrospectively analyzed. They were suspected of having GI anastomotic fistulas or had been found to have fluid collections with ultrasound that were accompanied by abdominal pain or fever after surgical procedures. Forty-two patients met the inclusion criteria and were enrolled into this study. Twenty-two were confirmed to have GI fistulas confirmed by standard references. None were detected by conventional ultrasound. Although IC-CEUS successfully detected GI fistulas in 16 patients, it missed GI fistulas in 6 patients. One patient was misdiagnosed with a GI fistula. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the diagnosis of GI fistulas by IC-CEUS were 72.7% (16/22), 95.0% (19/20), 94.1% (16/17), 76.0% (19/25) and 83.3% (35/42), respectively. Twenty peritoneal fluid collections in 14 patients were related to fistulas by IC-CEUS based on the distribution of ultrasound contrast agents. Additional drainage was performed in 14 fistula-related fluid collections. Eight GI fistulas were judged to be cured after IC-CEUS re-evaluation, and the drainage tubes were removed from these patients. In conclusion, IC-CEUS can greatly improve the ability to diagnose post-surgical GI fistulas and may also play an important role in interventional treatment and follow-up.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Xu EJ, Zhang M, Li K, et al. Intracavitary Contrast-Enhanced Ultrasound in the Management of Post-Surgical Gastrointestinal Fistulas. Ultrasound Med Biol. 2017. PMID: 29229267. doi:10.1016/j.ultrasmedbio.2017.10.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。