文献速递技术与安全腹部US

比较体格检查与相同检查技术的超声版本对脾肿大的诊断价值

Comparing Physical Examination With Sonographic Versions of the Same Examination Techniques for Splenomegaly.
PubMed 文献 · J Ultrasound Med · 2017-12-08

本研究在血液科门诊患者中比较传统体格检查(Castell法、脾尖触诊)与其超声版本对脾肿大的诊断准确性,以专业超声技师测量为参考标准。超声Castell法敏感度91.7%(95%CI 61.5%-99.8%)高于传统Castell法83.3%(95%CI 51.6%-97.9%),但耗时更长(28.8±18.6秒 vs 18.8±8.1秒,P=0.01);超声脾尖法敏感度58.3%(95%CI 27.7%-84.8%)高于触诊33.3%(95%CI 9.9%-65.1%),两者特异度均为100%。作者推荐床旁评估脾肿大时联合使用传统体格检查与超声技术。

要点

  • 超声Castell法诊断脾肿大敏感度91.7%,高于传统Castell法的83.3%。
  • 超声脾尖法敏感度58.3%,高于触诊的33.3%,两者特异度均为100%。
  • 超声版本操作时间更长:超声Castell法28.8±18.6秒 vs 传统法18.8±8.1秒(P=0.01)。

核心结论

  • 传统体格检查手法的超声版本比其对应的体格检查手法诊断准确性更高,但操作时间可能更长;作者推荐床旁评估脾肿大时联合使用传统体格检查和超声技术。

研究设计与样本

  • 研究在 urban hematology clinic 招募患者,由两名受过床旁超声培训的临床医生分别用传统叩诊和触诊技术(Castell法和脾尖触诊)及其超声版本(超声Castell法和超声脾尖法)检查脾肿大,结果与基于专业超声技师测量的参考标准比较。

诊断标准与关键数值

  • 以专业超声技师测量为参考标准,超声Castell法诊断脾肿大敏感度91.7%(95%CI 61.5%-99.8%),传统Castell法敏感度83.3%(95%CI 51.6%-97.9%);超声脾尖法敏感度58.3%(95%CI 27.7%-84.8%),触诊脾尖法敏感度33.3%(95%CI 9.9%-65.1%);触诊和超声脾尖法阳性结果特异度均为100%。

临床应用与阅片要点

  • 作者推荐在床旁评估脾肿大时联合使用传统体格检查和超声技术;超声Castell法较传统Castell法敏感度更高但耗时更长(28.8±18.6秒 vs 18.8±8.1秒,P=0.01),超声脾尖法较触诊敏感度更高,两者特异度均为100%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine whether sonographic versions of physical examination techniques can accurately identify splenomegaly, Castell's method (Ann Intern Med 1967; 67:1265-1267), the sonographic Castell's method, spleen tip palpation, and the sonographic spleen tip technique were compared with reference measurements.

METHODS: Two clinicians trained in bedside sonography patients recruited from an urban hematology clinic. Each patient was examined for splenomegaly using conventional percussion and palpation techniques (Castell's method and spleen tip palpation, respectively), as well as the sonographic versions of these maneuvers (sonographic Castell's method and sonographic spleen tip technique). Results were compared with a reference standard based on professional sonographer measurements.

RESULTS: The sonographic Castell's method had greater sensitivity (91.7% [95% confidence interval, 61.5% to 99.8%]) than the traditional Castell's method (83.3% [95% confidence interval, 51.6% to 97.9%]) but took longer to perform [mean ± SD, 28.8 ± 18.6 versus 18.8 ± 8.1 seconds; P = .01). Palpable and positive sonographic spleen tip results were both 100% specific, but the sonographic spleen tip method was more sensitive (58.3% [95% confidence interval, 27.7% to 84.8%] versus 33.3% [95% confidence interval, 9.9% to 65.1%]).

CONCLUSIONS: Sonographic versions of traditional physical examination maneuvers have greater diagnostic accuracy than the physical examination maneuvers from which they are derived but may take longer to perform. We recommend a combination of traditional physical examination and sonographic techniques when evaluating for splenomegaly at the bedside.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Cessford T, Meneilly GS, Arishenkoff S, et al. Comparing Physical Examination With Sonographic Versions of the Same Examination Techniques for Splenomegaly. J Ultrasound Med. 2017. PMID: 29219201. doi:10.1002/jum.14506

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。