超声-超声图像叠加融合改善肝细胞癌射频消融边界的实时控制
回顾性纳入53例患者共68个肝细胞癌病灶(0.9-4.0 cm),评估超声-超声图像叠加融合引导射频消融的可行性,并与消融后数日动态CT评估早期疗效对比;融合图像预测CT早期评估的准确率为92.6%(63/68),Kappa值为0.67(95%CI:0.39-0.95)。
要点
- 超声-超声图像叠加融合可在射频消融过程中三维显示消融边界。
- 术中可视化边界可提示立即补充治疗。
- 融合图像与早期评估CT结果相关,预测准确率92.6%(63/68)。
核心结论
- 超声-超声图像叠加融合可作为射频消融中实现安全边界的可行引导方式,并以高准确率预测早期疗效评估。
研究设计与样本
- 回顾性研究,纳入53例患者共68个肝细胞癌病灶(0.9-4.0 cm),均接受超声-超声叠加图像融合引导的射频消融,消融后数日行动态CT评估早期疗效。
关键影像表现/征象
- 通过叠加术前与术后超声,可将肿瘤图像投射至消融后高回声区。
- 术中可三维显示消融边界。
- 单次 session 即实现技术有效消融。
诊断标准与关键数值
- 以消融后数日动态CT为参考,59个病灶(86.8%)成功获得5 mm边界。
- 超声-超声图像叠加融合预测早期CT评估的准确率为92.6%(63/68),Kappa值为0.67(95%CI:0.39-0.95)。
临床应用与阅片要点
- 超声-超声图像叠加融合可在射频消融过程中实时显示消融边界。
- 术中显示边界可提示立即补充治疗。
- 融合图像结果与早期评估CT相关。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the clinical feasibility of US-US image overlay fusion with evaluation of the ablative margin in radiofrequency ablation (RFA) for hepatocellular carcinoma (HCC).
METHODS: Fifty-three patients with 68 HCCs measuring 0.9-4.0 cm who underwent RFA guided by US-US overlay image fusion were included in this retrospective study. By an overlay of pre-/postoperative US, the tumor image could be projected onto the ablative hyperechoic zone. Therefore, the ablative margin three-dimensionally could be shown during the RFA procedure. US-US image overlay was compared to dynamic CT a few days after RFA for assessment of early treatment response. Accuracy of graded response was calculated, and the performance of US-US image overlay fusion was compared with that of CT using a Kappa agreement test.
RESULTS: Technically effective ablation was achieved in a single session, and 59 HCCs (86.8 %) succeeded in obtaining a 5-mm margin on CT. The response with US-US image overlay correctly predicted early CT evaluation with an accuracy of 92.6 % (63/68) (k = 0.67; 95 % CI: 0.39-0.95).
CONCLUSION: US-US image overlay fusion can be proposed as a feasible guidance in RFA with a safety margin and predicts early response of treatment assessment with high accuracy.
KEY POINTS: • US-US image overlay fusion visualizes the ablative margin during RFA procedure. • Visualizing the margin during the procedure can prompt immediate complementary treatment. • US image fusion correlates with the results of early evaluation CT.
引用
- Minami Y, Minami T, Hagiwara S, et al. Ultrasound-ultrasound image overlay fusion improves real-time control of radiofrequency ablation margin in the treatment of hepatocellular carcinoma. Eur Radiol. 2017. PMID: 29196855. doi:10.1007/s00330-017-5162-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。