文献速递心血管外周血管其他

冠状动脉斑块微结构与组成改变光学偏振:光学频域成像的一种新内源性对比机制

Coronary Plaque Microstructure and Composition Modify Optical Polarization: A New Endogenous Contrast Mechanism for Optical Frequency Domain Imaging.
PubMed 文献 · JACC Cardiovasc Imaging · 2017-12-13

研究用改良光学频域成像系统在5颗尸检人心脏冠状动脉行偏振测量,并与组织学对照。纤维组织双折射显著高于轻微异常内膜组织(0.44×10-3 vs 0.33×10-3,p<0.0001),中膜双折射最高;坏死核心和富脂区域去偏振显著(p<0.0001)。偏振测量可经常规导管获得,为表征斑块组成提供定量指标。

要点

  • 纤维组织双折射显著高于轻微异常内膜组织,中膜双折射最高。
  • 坏死核心和富脂区域去偏振显著,胆固醇结晶和巨噬细胞处亦可见去偏振。
  • 改良OFDI系统经常规导管可同时获得偏振测量与常规横断面图像。

核心结论

  • 使用常规OFDI导管结合改良主机和信号处理算法,可获得血管内双折射和去偏振测量,为常规OFDI提供组织组成相关附加信息及表征斑块特征的定量指标。

研究设计与样本

  • 在5颗尸检人心脏的主要冠状动脉上,用可提供偏振评估的OFDI系统成像,重建双折射(折射率单位)和去偏振(去偏振信号与总强度之比)横断面图,随后行组织学评估以解读各组织成分的偏振特征。

关键影像表现/征象

  • 纤维组织双折射显著高于轻微异常内膜组织(0.44×10-3 vs 0.33×10-3,p<0.0001)。
  • 中膜双折射最高(p<0.0001),与其高平滑肌细胞含量一致。
  • 纤维区域双折射显示精细空间特征,与胶原组织学表现密切对应。
  • 坏死核心和富脂区域引起显著去偏振(p<0.0001)。
  • 胆固醇结晶和巨噬细胞所在位置也可见去偏振。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to evaluate whether polarimetry, performed using a modified optical frequency domain imaging (OFDI) system, can improve the assessment of histological features relevant to characterizing human coronary atherosclerosis.

BACKGROUND: The microscopic structure and organization of the arterial wall influence the polarization of the infrared light used by OFDI. Modification of the OFDI apparatus, along with recently developed image reconstruction methods, permits polarimetric measurements simultaneously with conventional OFDI cross-sectional imaging through standard intravascular imaging catheters.

METHODS: The main coronary arteries of 5 cadaveric human hearts were imaged with an OFDI system capable of providing polarimetric assessment. Cross-sectional views of tissue birefringence, measured in refractive index units, and depolarization, expressed as the ratio of depolarized signal to total intensity, were reconstructed, together with conventional OFDI images. Following imaging, the vessels underwent histological evaluation to enable interpretation of the observed polarization features of individual tissue components.

RESULTS: Birefringence in fibrous tissue was significantly higher than in intimal tissue with minimal abnormality (0.44 × 10-3 vs. 0.33 × 10-3; p < 0.0001). Birefringence was highest in the tunica media (p < 0.0001), consistent with its high smooth muscle cell content, cells known to associate with birefringence. In fibrous areas, birefringence showed fine spatial features and close correspondence with the histological appearance of collagen. In contrast, necrotic cores and regions rich in lipid elicited significant depolarization (p < 0.0001). Depolarization was also evident in locations of cholesterol crystals and macrophages.

CONCLUSIONS: Intravascular measurements of birefringence and depolarization can be obtained using conventional OFDI catheters in conjunction with a modified console and signal processing algorithms. Polarimetric measurements enhance conventional OFDI by providing additional information related to the tissue composition and offer quantitative metrics enabling characterization of plaque features.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Villiger M, Otsuka K, Karanasos A, et al. Coronary Plaque Microstructure and Composition Modify Optical Polarization: A New Endogenous Contrast Mechanism for Optical Frequency Domain Imaging. JACC Cardiovasc Imaging. 2017. PMID: 29248662. doi:10.1016/j.jcmg.2017.09.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。