对比剂浓度对低千伏计算机断层扫描血管成像的影响:一项系统性临床前研究

Impact of Contrast Media Concentration on Low-Kilovolt Computed Tomography Angiography: A Systematic Preclinical Approach.
PubMed 文献 · Invest Radiol · 2018-01-01

在7只猪模型上行70 kVp动态CTA,比较三种总碘量及碘流率相同但碘浓度和流率不同的方案。结果显示方案B(300 mg I/mL)动脉峰值强化优于方案A(400 mg I/mL),方案C(150 mg I/mL)与方案B无显著差异且不降低血管强化。

要点

  • 70 kVp CTA中保持碘流率恒定时,300 mg I/mL方案动脉峰值强化优于400 mg I/mL方案。
  • 碘浓度低至150 mg I/mL仍可获得与300 mg I/mL相当的血管强化。
  • 注射流率越高,达峰时间越短,团注追踪延迟时间亦相应缩短。

核心结论

  • 在70 kVp CTA中,保持碘流率恒定时,300 mg I/mL碘浓度方案血管强化优于高浓度对比剂;150 mg I/mL碘浓度亦可在不损害血管强化的情况下使用。

研究设计与样本

  • 系统性临床前动物实验,在7只猪上使用第三代双源CT系统行70 kVp动态CTA,三种对比剂注射方案随机顺序自身对照,并在单期CTA中验证最佳参数的可重复性。

诊断标准与关键数值

  • 方案A为400 mg I/mL、1.9 mL/s;方案B为300 mg I/mL、2.5 mL/s;方案C为150 mg I/mL、5 mL/s;三者总碘量均为150 mg I/kg、注射时间12秒、碘流率0.75 g I/s。动态扫描平均动脉峰值强化:方案A 359 ± 51 HU,方案B 382 ± 36 HU,方案C 382 ± 60 HU(A与B及C比较P < 0.01;B与C比较P = 0.995)。

临床应用与阅片要点

  • 在70 kVp CTA协议中,保持碘流率恒定时可考虑使用300 mg I/mL碘浓度以获得优于400 mg I/mL的动脉峰值强化;150 mg I/mL碘浓度亦可在不损害血管强化的情况下使用。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Low peak kilovoltage (kVp) protocols in computed tomography angiography (CTA) demand a review of contrast media (CM) administration practices. The aim of this study was to systematically evaluate different iodine concentrations of CM in a porcine model.

MATERIALS AND METHODS: Dynamic 70 kVp CTA was performed on 7 pigs using a third-generation dual-source CT system. Three CM injection protocols (A-C) with an identical total iodine dose and iodine delivery rate (150 mg I/kg, 12 s, 0.75 g I/s) differed in iodine concentration and flow rate (protocol A: 400 mg I/mL, 1.9 mL/s; B: 300 mg I/mL, 2.5 mL/s; C: 150 mg I/mL, 5 mL/s). All protocols were applied in a randomized order and compared intraindividually. Arterial enhancement at different locations in the pulmonary artery, the aorta, and aortic branches was measured over time. Time attenuation curves, peak enhancement, time to peak, and bolus tracking delay times needed for static CTA were calculated. The reproducibility of optimal parameters was tested in single-phase CTA.

RESULTS: The heart rates of the pigs were comparable for all protocols (P > 0.7). The injection pressure was significantly higher for protocol A (64 ± 5 psi) and protocol C (55 ± 3 psi) compared with protocol B (39 ± 2 psi) (P < 0.001). Average arterial peak enhancement in the dynamic scans was 359 ± 51 HU (protocol A), 382 ± 36 HU (B), and 382 ± 60 HU (C) (A compared with B and C: P < 0.01; B compared with C: P = 0.995). Time to peak enhancement decreased with increasing injection rate. The delay time for bolus tracking depended on the injection rate as well and was highest for protocol A (4.7 seconds) and lowest for protocol C (3.9 seconds) (P = 0.038). The peak enhancement values of the dynamic scans highly correlated with those of the single-phase CTA scans.

CONCLUSIONS: In 70 kVp CTA, 300 mg I/mL iodine concentrations showed to be superior to high-concentration CM when keeping the iodine delivery rate constant. Besides, iodine concentrations as low as 150 mg I/mL can be administered without compromising vascular enhancement. This opens up new possibilities in CM administration.

来源:Invest Radiol,查看原文。版权归原作者所有。