文献速递心血管MR

心肌梗死的黑血延迟增强心脏磁共振成像

Dark-Blood Delayed Enhancement Cardiac Magnetic Resonance of Myocardial Infarction.
PubMed 文献 · JACC Cardiovasc Imaging · 2017-12-13

研究提出并验证了一种不依赖血流的延迟增强技术,可在显示高增强心肌的同时抑制血池信号。在犬模型(n=22)中,FIDDLE 检测心肌梗死的敏感度(96% vs 85%,p=0.002)和准确率(95% vs 87%,p=0.01)均优于常规 DE-CMR,特异度相似(92% vs 92%,p=1.0);在患者中 FIDDLE 诊断准确率亦高于 DE-CMR(100% [95%CI: 89%–100%] vs 84% [95%CI: 66%–95%],p=0.03)。

要点

  • FIDDLE 在显示高增强心肌的同时抑制血池信号,改善梗死心肌与邻近血池边界的区分。
  • 犬模型中 FIDDLE 检测 MI 的敏感度 96% vs 常规 DE-CMR 85%,准确率 95% vs 87%,特异度均为 92%。
  • 两种技术均识别的梗死灶中,FIDDLE 100% 可见梗死心肌与邻近血池间心内膜边界全长,DE-CMR 为 33%。

核心结论

  • 研究提出并验证了一种新的 CMR 技术,改善梗死心肌与邻近血池边界的区分,其诊断性能优于当前体内参考标准。

研究设计与样本

  • 以病理为参考标准的犬模型验证(n=22),并对心肌梗死患者和正常对照进行临床性能研究(n=31)。

关键影像表现/征象

  • FIDDLE 在显示高增强心肌的同时抑制血池信号,表现为黑血延迟增强。
  • 两种技术均识别的梗死灶中,梗死心肌与邻近血池间心内膜边界全长可见者 FIDDLE 为 100%,DE-CMR 为 33%。

诊断标准与关键数值

  • 犬模型:FIDDLE 检测 MI 敏感度 96% vs 常规 DE-CMR 85%(p=0.002),准确率 95% vs 87%(p=0.01),特异度 92% vs 92%(p=1.0)。
  • 患者:FIDDLE 诊断 MI 准确率 100%(95%CI: 89%–100%)vs DE-CMR 84%(95%CI: 66%–95%),p=0.03。
  • FIDDLE 测量梗死体积与参考标准的一致性优于 DE-CMR,95% 一致性界限分别为 2.1% 和 5.5%(p<0.0001)。

临床应用与阅片要点

  • FIDDLE 可改善梗死心肌与明亮左室血池之间边界的显示,有助于避免因边界不清而漏诊梗死。
  • 作者结论认为该黑血技术对 MI 的影像诊断性能优于当前体内参考标准。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study introduced and validated a novel flow-independent delayed enhancement technique that shows hyperenhanced myocardium while simultaneously suppressing blood-pool signal.

BACKGROUND: The diagnosis and assessment of myocardial infarction (MI) is crucial in determining clinical management and prognosis. Although delayed enhancement cardiac magnetic resonance (DE-CMR) is an in vivo reference standard for imaging MI, an important limitation is poor delineation between hyperenhanced myocardium and bright LV cavity blood-pool, which may cause many infarcts to become invisible.

METHODS: A canine model with pathology as the reference standard was used for validation (n = 22). Patients with MI and normal controls were studied to ascertain clinical performance (n = 31).

RESULTS: In canines, the flow-independent dark-blood delayed enhancement (FIDDLE) technique was superior to conventional DE-CMR for the detection of MI, with higher sensitivity (96% vs. 85%, respectively; p = 0.002) and accuracy (95% vs. 87%, respectively; p = 0.01) and with similar specificity (92% vs, 92%, respectively; p = 1.0). In infarcts that were identified by both techniques, the entire length of the endocardial border between infarcted myocardium and adjacent blood-pool was visualized in 33% for DE-CMR compared with 100% for FIDDLE. There was better agreement for FIDDLE-measured infarct size than for DE-CMR infarct size (95% limits-of-agreement, 2.1% vs. 5.5%, respectively; p < 0.0001). In patients, findings were similar. FIDDLE demonstrated higher accuracy for diagnosis of MI than DE-CMR (100% [95% confidence interval [CI]: 89% to 100%] vs. 84% [95% CI: 66% to 95%], respectively; p = 0.03).

CONCLUSIONS: The study introduced and validated a novel CMR technique that improves the discrimination of the border between infarcted myocardium and adjacent blood-pool. This dark-blood technique provides diagnostic performance that is superior to that of the current in vivo reference standard for the imaging diagnosis of MI.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Kim HW, Rehwald WG, Jenista ER, et al. Dark-Blood Delayed Enhancement Cardiac Magnetic Resonance of Myocardial Infarction. JACC Cardiovasc Imaging. 2017. PMID: 29248655. doi:10.1016/j.jcmg.2017.09.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。