文献速递胸部CT

术前应用四维超低剂量CT结合自适应迭代三维降噪评估胸膜粘连

Preoperative assessment of pleural adhesion by Four-Dimensional Ultra-Low-Dose Computed Tomography (4D-ULDCT) with Adaptive Iterative Dose Reduction using Three-Dimensional processing (AIDR-3D).
PubMed 文献 · Eur J Radiol · 2017-11-21

本研究对27例患者行单次呼吸周期内16cm覆盖的四维超低剂量CT(4D-ULDCT),以术中胸腔镜所见为参考标准,计算胸膜与肋骨外缘对应点距离随呼吸的变化幅度,发现下肺野的距离变化平均值与最大值、上肺野的距离变化平均值在无粘连、轻度粘连与重度粘连之间差异有统计学意义,提示4D-ULDCT可能用于术前无创评估胸膜粘连的存在与程度。

要点

  • 以术中胸腔镜所见为参考,4D-ULDCT可区分有无局限性胸膜粘连及其程度。
  • 下肺野胸膜-肋骨点距离平均变化值在无、轻、重度粘连间差异有统计学意义。
  • 上肺野仅距离平均变化值有统计学差异,最大值在轻度粘连与无粘连间相近。

核心结论

  • 4D-ULDCT可能成为术前无创评估局限性胸膜粘连存在与否及严重程度的有用方法。

研究设计与样本

  • 研究类型为可行性评估研究,纳入27例患者,于单次呼吸周期内行4D-ULDCT,体轴覆盖16cm。
  • 以术中胸腔镜所见确认局限性胸膜粘连的存在与严重程度作为参考标准。
  • 在吸气末同一轴位层面分别放置胸膜点与肋骨外缘对应点,经自动追踪功能计算各呼吸时相两点距离(PCD)。

关键影像表现/征象

  • 上肺野(支气管分叉以上)测量点:无粘连110个、轻度粘连16个、重度粘连10个。
  • 下肺野(支气管分叉以下)测量点:无粘连150个、轻度粘连17个、重度粘连9个。
  • 下肺野PCD平均变化量在无、轻、重度粘连分别为18.1±9.2、12.3±6.2、5.0±3.3mm,差异有统计学意义(p<0.05)。
  • 上肺野PCD平均变化量在无、轻、重度粘连分别为9.2±5.5、5.7±2.8、2.2±0.4mm,差异有统计学意义(p<0.05);上肺野PCD最大变化量在轻度粘连为12.3±5.9mm、无粘连为17.5±11.0mm,二者相近。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the feasibility of Four-Dimensional Ultra-Low-Dose Computed Tomography (4D-ULDCT) for distinguishing pleural aspects with localized pleural adhesion (LPA) from those without.

METHODS: Twenty-seven patients underwent 4D-ULDCT during a single respiration with a 16cm-coverage of the body axis. The presence and severity of LPA was confirmed by their intraoperative thoracoscopic findings. A point on the pleura and a corresponding point on the outer edge of the costal bone were placed in identical axial planes at end-inspiration. The distance of the two points (PCD), traced by automatic tracking functions respectively, was calculated at each respiratory phase. The maximal and average change amounts in PCD (PCDMCA and PCDACA) were compared among 110 measurement points (MPs) without LPA, 16MPs with mild LPA and 10MPs with severe LPA in upper lung field cranial to the bronchial bifurcation (ULF), and 150MPs without LPA, 17MPs with mild LPA and 9MPs with severe LPA in lower lung field caudal to the bronchial bifurcation (LLF) using the Mann-Whitney U test.

RESULTS: In the LLF, PCDACA as well as PCDMCA demonstrated a significant difference among non-LPA, mild LPA and severe LPA (18.1±9.2, 12.3±6.2 and 5.0±3.3mm) (p<0.05). Also in the ULF, PCDACA showed a significant difference among three conditions (9.2±5.5, 5.7±2.8 and 2.2±0.4mm, respectively) (p<0.05), whereas PCDMCA for mild LPA was similar to that for non-LPA (12.3±5.9 and 17.5±11.0mm).

CONCLUSIONS: Four D-ULDCT could be a useful non-invasive preoperative assessment modality for the detection of the presence or severity of LPA.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Hashimoto M, Nagatani Y, Oshio Y, et al. Preoperative assessment of pleural adhesion by Four-Dimensional Ultra-Low-Dose Computed Tomography (4D-ULDCT) with Adaptive Iterative Dose Reduction using Three-Dimensional processing (AIDR-3D). Eur J Radiol. 2017. PMID: 29279160. doi:10.1016/j.ejrad.2017.11.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。