肺部亚实性结节:半自动测量在诊断准确性、诊断可重复性及结节分类一致性中的价值
研究纳入102个亚实性结节,由两名阅片者分别进行半自动与手动直径测量。半自动有效直径预测浸润性腺癌的AUC为0.905-0.923,优于手动平均直径的0.833-0.864(p<0.05),且诊断与分类的可重复性均提高。
要点
- 半自动有效直径预测浸润性腺癌的AUC为0.905-0.923,优于手动平均直径的0.833-0.864。
- 半自动测量使阅片者间诊断一致性κ从0.690提高到0.924(p=0.012)。
- 半自动测量使阅片者间亚实性结节分类一致性κ从0.683提高到0.861(p=0.022)。
核心结论
- 半自动有效直径测量有机会提高亚实性结节的诊断准确性、诊断可重复性及分类可重复性。
研究设计与样本
- 研究纳入102个亚实性结节,两名阅片者独立进行半自动与手动直径及实性成分测量,以logistic回归和ROC曲线评估诊断效能,用Cohen's κ统计评估可重复性。
诊断标准与关键数值
- 半自动有效直径预测浸润性腺癌的AUC为0.905-0.923,手动平均直径的AUC为0.833-0.864(p<0.05);阅片者间诊断κ半自动为0.924、手动为0.690(p=0.012);阅片者间按Fleischner指南分类的κ半自动为0.861、手动为0.683(p=0.022)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: We hypothesized that semi-automatic diameter measurements would improve the accuracy and reproducibility in discriminating preinvasive lesions and minimally invasive adenocarcinomas from invasive pulmonary adenocarcinomas appearing as subsolid nodules (SSNs) and increase the reproducibility in classifying SSNs.
METHODS: Two readers independently performed semi-automatic and manual measurements of the diameters of 102 SSNs and their solid portions. Diagnostic performance in predicting invasive adenocarcinoma based on diameters was tested using logistic regression analysis with subsequent receiver operating characteristic curves. Inter- and intrareader reproducibilities of diagnosis and SSN classification according to Fleischner's guidelines were investigated for each measurement method using Cohen's κ statistics.
RESULTS: Semi-automatic effective diameter measurements were superior to manual average diameters for the diagnosis of invasive adenocarcinoma (AUC, 0.905-0.923 for semi-automatic measurement and 0.833-0.864 for manual measurement; p<0.05). Reproducibility of diagnosis between the readers also improved with semi-automatic measurement (κ=0.924 for semi-automatic measurement and 0.690 for manual measurement, p=0.012). Inter-reader SSN classification reproducibility was significantly higher with semi-automatic measurement (κ=0.861 for semi-automatic measurement and 0.683 for manual measurement, p=0.022).
CONCLUSIONS: Semi-automatic effective diameter measurement offers an opportunity to improve diagnostic accuracy and reproducibility as well as the classification reproducibility of SSNs.
KEY POINTS: • Semi-automatic effective diameter measurement improves the diagnostic accuracy for pulmonary subsolid nodules. • Semi-automatic measurement increases the inter-reader agreement on the diagnosis for subsolid nodules. • Semi-automatic measurement augments the inter-reader reproducibility for the classification of subsolid nodules.
引用
- Kim H, Park CM, Hwang EJ, et al. Pulmonary subsolid nodules: value of semi-automatic measurement in diagnostic accuracy, diagnostic reproducibility and nodule classification agreement. Eur Radiol. 2017. PMID: 29196857. doi:10.1007/s00330-017-5171-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。