文献速递胸部CT

CT窗设置与重建平面对表现为亚实性结节的肺腺癌第8版T分期分类的影响

Effect of computed tomography window settings and reconstruction plane on 8th edition T-stage classification in patients with lung adenocarcinoma manifesting as a subsolid nodule.
PubMed 文献 · Eur J Radiol · 2017-11-22

回顾性纳入221例患者247个亚实性结节,比较肺窗与纵隔窗、轴位与多平面测量实性部分直径对第8版T分期的影响。纵隔窗读者间一致性更稳定,肺窗CT与病理测量相关性更好;不同窗设置下临床T分期不一致比例最高达49.0%,多平面测量致分期上调最高达24.3%。

要点

  • 纵隔窗读者间一致性良好至优秀(ICC CI 0.77-0.95),肺窗为中等至优秀(0.51-0.92)。
  • 肺窗CT与病理测量相关性良好至优秀(ICC CI 0.63-0.82),纵隔窗为一般至良好(0.25-0.78)。
  • 多平面测量较单纯轴位测量致临床T分期上调:纵隔窗12.6%-15.8%,肺窗19.0%-24.3%。

核心结论

  • 纵隔窗在读者间一致性方面更稳定,但肺窗CT测量与病理测量相关性更好;临床T分期随窗设置不同在最高近半数病例中发生变化,多平面测量致最高约四分之一病例分期上调。

研究设计与样本

  • 回顾性研究,纳入2012年2月至2015年10月间因肺腺癌手术的221例患者共247个亚实性结节,两名放射科医师独立在轴位、冠状位和矢状位采用肺窗和纵隔窗测量实性部分直径,以三个平面最大径为多平面测量值。

关键影像表现/征象

  • 亚实性结节实性部分直径在肺窗与纵隔窗、轴位与多平面测量间存在差异,导致临床T分期不一致。
  • 纵隔窗读者间一致性ICC置信区间为0.77-0.95,肺窗为0.51-0.92。
  • 肺窗CT与病理测量ICC置信区间为0.63-0.82,纵隔窗为0.25-0.78。

诊断标准与关键数值

  • 基于第8版TNM标准,以实性部分最大径判定临床T分期。
  • 纵隔窗与肺窗临床T分期不一致比例:轴位测量32.0%-41.7%,多平面测量33.6%-49.0%。
  • 多平面测量较轴位测量致分期上调比例:纵隔窗12.6%-15.8%,肺窗19.0%-24.3%。
  • 临床T分期与病理T分期一致性的κ值为0.53-0.69。

临床应用与阅片要点

  • 测量亚实性结节实性部分时需注意窗设置对直径及T分期的影响,纵隔窗读者间一致性更稳定。
  • 多平面测量较轴位测量可致部分病例T分期上调,报告时应注明测量所用窗与平面。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the effect of window settings and reconstruction plane on clinical T-stage determined by solid portion size within subsolid nodules (SSNs), based on 8th-edition TNM standards.

MATERIALS AND METHODS: This retrospective study included 247 SSNs from 221 patients who underwent surgery for lung adenocarcinomas between Feb 2012 and Oct 2015. Two radiologists independently measured the diameter of the solid portion on axial, coronal, and sagittal planes using lung- and mediastinal-window. The largest diameter among the measurements on the three planes was referred to as multiplanar measurement. Inter-reader agreement as well as the correlation between the CT and pathologic measurements were calculated using intra-class correlation coefficients (ICCs). The proportions of disagreement in clinical T-stage on different measurement methods were measured. The κ values for agreement between clinical- and pathological T-stage were measured.

RESULTS: Inter-reader agreement was moderate-to-excellent (ICC confidence interval [CI] range, 0.51-0.92) in lung-window, while it was good-to-excellent (0.77-0.95) in mediastinal-window. The correlation between the CT and pathologic measurements was good-to-excellent (ICC CI range, 0.63-0.82) in lung-window and fair-to-good (0.25-0.78) in mediastinal-window. The proportions of disagreement between clinical T-stages using mediastinal- and lung-window were 32.0%-41.7% and 33.6%-49.0% with axial and multiplanar measurement, respectively. Multiplanar measurement resulted in upstaging in 12.6%-15.8% and 19.0%-24.3% of cases with mediastinal- and lung-window, respectively, when compared with axial measurement alone. The κ values for agreement between clinical T-stage and pathological T-stage ranged from 0.53 to 0.69.

CONCLUSIONS: Mediastinal-window was a more stable method in the aspect of the inter-reader agreement, but the correlation between the CT and pathologic measurement was better in lung-window. The clinical T-stage varied in up to one-half of the cases according to the window setting, and multiplanar measurement resulted in upstaging in up to one-fourth of the cases.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ahn H, Lee KW, Lee KH, et al. Effect of computed tomography window settings and reconstruction plane on 8th edition T-stage classification in patients with lung adenocarcinoma manifesting as a subsolid nodule. Eur J Radiol. 2017. PMID: 29279151. doi:10.1016/j.ejrad.2017.11.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。