小肺病灶术前短钩丝定位:技术成功率及初始置入失败危险因素评估
回顾性评估401例小肺病灶(平均直径9.3 mm)CT透视引导下术前短钩丝定位的技术成功率并分析初始置入失败危险因素。383/401例初始置入成功,18例失败,最终399/401病灶(99.5%)成功置入。经叶裂途径是所有操作初始置入失败的独立预测因素(OR 15.326),常规途径中小病灶是失败独立预测因素(OR 0.793)。
要点
- 短钩丝定位技术成功率极高,最终99.5%病灶成功置入。
- 经叶裂途径显著增加初始置入失败风险(OR 15.326)。
- 常规途径中病灶越小,初始置入失败风险越高(OR 0.793)。
核心结论
- 术前短钩丝定位技术成功率极高;经叶裂途径是所有操作初始置入失败的独立预测因素,小病灶是常规途径操作初始置入失败的独立预测因素。
研究设计与样本
- 回顾性研究,共401例短钩丝置入(对应401个病灶,平均直径9.3 mm),评估CT透视引导下术前短钩丝定位的技术成功率及初始置入失败危险因素。
诊断标准与关键数值
- 技术成功定义为钩丝正确定位。
- 所有操作中,经叶裂途径是初始置入失败的独立预测因素(OR 15.326;95%CI 5.429-43.267;p < 0.001)。
- 常规途径操作的374例中,病灶大小是初始置入失败的独立预测因素(OR 0.793;95%CI 0.631-0.996;p = 0.046)。
局限性
- 原文为回顾性评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To retrospectively evaluate the technical success of computed tomography fluoroscopy-guided short hookwire placement before video-assisted thoracoscopic surgery and to identify the risk factors for initial placement failure.
METHODS: In total, 401 short hookwire placements for 401 lesions (mean diameter 9.3 mm) were reviewed. Technical success was defined as correct positioning of the hookwire. Possible risk factors for initial placement failure (i.e., requirement for placement of an additional hookwire or to abort the attempt) were evaluated using logistic regression analysis for all procedures, and for procedures performed via the conventional route separately.
RESULTS: Of the 401 initial placements, 383 were successful and 18 failed. Short hookwires were finally placed for 399 of 401 lesions (99.5%). Univariate logistic regression analyses revealed that in all 401 procedures only the transfissural approach was a significant independent predictor of initial placement failure (odds ratio, OR, 15.326; 95% confidence interval, CI, 5.429-43.267; p < 0.001) and for the 374 procedures performed via the conventional route only lesion size was a significant independent predictor of failure (OR 0.793, 95% CI 0.631-0.996; p = 0.046).
CONCLUSIONS: The technical success of preoperative short hookwire placement was extremely high. The transfissural approach was a predictor initial placement failure for all procedures and small lesion size was a predictor of initial placement failure for procedures performed via the conventional route.
KEY POINTS: • Technical success of preoperative short hookwire placement was extremely high. • The transfissural approach was a significant independent predictor of initial placement failure for all procedures. • Small lesion size was a significant independent predictor of initial placement failure for procedures performed via the conventional route.
引用
- Iguchi T, Hiraki T, Matsui Y, et al. Preoperative short hookwire placement for small pulmonary lesions: evaluation of technical success and risk factors for initial placement failure. Eur Radiol. 2017. PMID: 29247354. doi:10.1007/s00330-017-5176-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。