半球光声成像对心肌梗死的在体检测与监测
本研究在Balb/c小鼠中结扎左前降支诱导心肌缺血,采用128个螺旋分布超声换能器、并行数据采集的半球光声成像系统进行在体成像。结果显示该系统可勾勒胸部血管和整个心脏形态,纵向图像显示梗死区逐渐扩大伴坏死和纤维化,光声信号强度较健康心肌降低约2.5倍,心脏增大面积约18%,定量结果与酶学及组织学检查高度一致。
要点
- 半球光声成像可无创定位和表征小鼠在体心肌梗死,成像深度达10 mm。
- 心梗后光声信号强度较健康心肌降低约2.5倍,心脏面积增大~18%。
- 光声成像可作为SPECT和超声成像的补充模态。
核心结论
- 光声成像凭借深部器官成像和病灶区域鉴别能力,可实现心肌梗死的诊断和损伤定位。
研究设计与样本
- 在体动物研究,采用Balb/c小鼠结扎左前降支诱导缺血,使用半球光声成像系统(128个螺旋分布超声换能器、并行数据采集)成像,以三苯基四氮唑氯化物染色定量验证。
关键影像表现/征象
- 半球光声成像可勾勒胸部血管和整个心脏形态。
- 纵向光声图像显示梗死区逐渐扩大,伴坏死和纤维化。
- 心梗建模后光声信号强度降低399.1 ± 56.3(p < 0.001),较健康心肌组织降低约2.5倍。
- 心脏增大面积计算为10.4 ± 6.0 mm2(p < 0.001),较健康心脏增大~18%。
临床应用与阅片要点
- 光声成像可在10 mm成像深度诊断心肌梗死病灶。
- 定量结果与酶学和组织学检查高度一致。
- 光声成像可作为SPECT和超声成像的补充模态。
局限性
- 本研究为在体动物实验,结论基于Balb/c小鼠模型。
- 作者指出本研究将鼓励光声成像进一步向临床用途发展。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to demonstrate the capacity for noninvasive localisation and characterisation of myocardial infarction (MI) in vivo using a hemispherical photoacoustic imaging (PAI) system. MI remains a leading cause of morbidity and mortality worldwide. To enable optimal treatment of patients, timely and accurate diagnosis and longitudinal monitoring is critical.
METHODS: Ischaemia was induced in Balb/c mice by ligation of the left anterior descending artery. The hemispherical PAI system, equipped with 128 ultrasonic transducers spirally distributed on the surface, along with parallel data acquisition, was applied for imaging of the mouse heart.
RESULTS: Our study showed that hemispherical PAI can delineate thoracic vessels and the morphology of the entire heart. Longitudinal PAI images revealed gradual expansion of the infarcted area along with necrosis and fibrosis, which were quantitatively validated by triphenyltetrazolium chloride staining. After MI modelling, the photoacoustic (PA) signal intensity decreased by 399.1 ± 56.3 (p < 0.001), a ~2.5-fold reduction compared to that of healthy cardiac tissue. The calculated size of the enlarged heart, 10.4 ± 6.0 mm2 (p < 0.001), represents an increase of ~18% versus that of a healthy heart.
CONCLUSIONS: PAI enables MI diagnosis and injury localisation with its capabilities for both deep organ imaging and lesion region differentiation.
KEY POINTS: • Photoacoustic imaging (PAI), combining optical absorption and ultrasonic resolution, can delineate cardiac anatomy. • PAI can diagnose myocardial infarction lesions with 10 mm imaging depth in vivo. • Quantified results are in excellent agreement with enzyme and histological examinations. • PAI can serve as a complementary modality to SPECT and ultrasound imaging. • This study will encourage further PAI development for clinical use.
引用
- Lv J, Peng Y, Li S, et al. Hemispherical photoacoustic imaging of myocardial infarction: in vivo detection and monitoring. Eur Radiol. 2017. PMID: 29270643. doi:10.1007/s00330-017-5209-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。