文献速递神经技术与安全MR

同步多层加速半傅里叶采集单次激发快速自旋回波(HASTE)成像的临床应用

Clinical application of Half Fourier Acquisition Single Shot Turbo Spin Echo (HASTE) imaging accelerated by simultaneous multi-slice acquisition.
PubMed 文献 · Eur J Radiol · 2017-12-02

研究将多频带激发与PINS重聚焦脉冲整合入HASTE序列(MB-PINS HASTE),在Siemens 3T-Prisma系统上对10名个体行全脑扫描并与临床HASTE协议比较。结果显示MB-PINS HASTE采集速度约为临床HASTE的2倍,整体脑部、白质病变、组织丢失区及脑脊液间隙的诊断图像质量相当,但伪影更频繁。

要点

  • MB-PINS HASTE较临床HASTE采集速度约提升2倍。
  • 整体脑部、白质改变、组织丢失区及脑脊液间隙的诊断图像质量两者相当。
  • MB-PINS HASTE伪影出现更频繁。

核心结论

  • MB-PINS HASTE可采集层面加速的高度T2加权图像,在缩短采集时间的同时提供良好的诊断图像质量。

研究设计与样本

  • 在Siemens 3T-Prisma系统上对10名个体行全脑MB-PINS HASTE扫描,并与临床HASTE协议比较;序列整合多频带激发、PINS重聚焦脉冲、blipped CAIPIRINHA与TRAPS,含内部FLASH参考扫描用于在线重建。

关键影像表现/征象

  • MB-PINS HASTE较临床HASTE采集速度约提升2倍。
  • 整体脑部、白质改变、组织丢失区及脑脊液间隙的诊断图像质量两者相当。
  • MB-PINS HASTE伪影出现更频繁。

临床应用与阅片要点

  • 不配合及年轻患者可能从MB-PINS HASTE序列的速度中获益,临床诊断可能无需镇静。

局限性

  • MB-PINS HASTE伪影较临床HASTE更频繁。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

As a single-shot sequence with a long train of refocusing pulses, Half-Fourier Acquisition Single-Shot Turbo-Spin-Echo (HASTE) suffers from high power deposition limiting use at high resolutions and high field strengths, particularly if combined with acceleration techniques such as simultaneous multi-slice (SMS) imaging. Using a combination of multiband (MB)-excitation and PINS-refocusing pulses will effectively accelerate the acquisition time while staying within the SAR limitations. In particular, uncooperative and young patients will profit from the speed of the MB-PINS HASTE sequence, as clinical diagnosis can be possible without sedation. Materials and MethodsMB-excitation and PINS-refocusing pulses were incorporated into a HASTE-sequence with blipped CAIPIRINHA and TRAPS including an internal FLASH reference scan for online reconstruction. Whole brain MB-PINS HASTE data were acquired on a Siemens 3T-Prisma system from 10 individuals and compared to a clinical HASTE protocol. ResultsThe proposed MB-PINS HASTE protocol accelerates the acquisition by about a factor 2 compared to the clinical HASTE. The diagnostic image quality proved to be comparable for both sequences for the evaluation of the overall aspect of the brain, the detection of white matter changes and areas of tissue loss, and for the evaluation of the CSF spaces although artifacts were more frequently encountered with MB-PINS HASTE. ConclusionsMB-PINS HASTE enables acquisition of slice accelerated highly T2-weighted images and provides good diagnostic image quality while reducing acquisition time.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Schulz J, P Marques J, Ter Telgte A, et al. Clinical application of Half Fourier Acquisition Single Shot Turbo Spin Echo (HASTE) imaging accelerated by simultaneous multi-slice acquisition. Eur J Radiol. 2017. PMID: 29279164. doi:10.1016/j.ejrad.2017.11.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。