儿童脑内钆沉积:反复给予钆基对比剂后齿状核T1加权高信号
该回顾性研究纳入41例18岁以下、2005至2015年间至少接受4次脑增强MRI的患儿,手动勾画双侧齿状核并计算齿状核-脑桥信号强度比。首次与末次MRI相比该比值显著升高(1.05对1.11,p=0.004),控制诊断、放化疗史、性别和年龄后,该比值与累积钆剂量呈显著正相关(系数=0.401,p=0.032)。
要点
- 儿童反复接受钆基对比剂后,齿状核T1加权信号较首次检查升高。
- 齿状核-脑桥信号强度比与累积钆剂量独立正相关(系数=0.401,p=0.032)。
- 阅片时可将齿状核-脑桥信号强度比作为评估钆沉积的参考指标。
核心结论
- 儿童反复给予钆基对比剂与齿状核T1加权信号强度增高相关。
研究设计与样本
- 经机构审查委员会批准的回顾性研究,符合《健康保险流通与责任法案》;纳入41例18岁以下、2005至2015年间至少接受4次脑增强MRI的患儿;手动勾画双侧齿状核,计算齿状核-脑桥信号强度比,采用线性混合效应模型控制混杂变量。
关键影像表现/征象
- 齿状核-脑桥信号强度比从首次MRI的1.05升至末次MRI的1.11(p=0.004)。
诊断标准与关键数值
- 齿状核-脑桥信号强度比与累积钆剂量的线性混合效应模型系数=0.401(p=0.032),已控制患者诊断、化疗或放疗史、性别和年龄。
临床应用与阅片要点
- 儿童多次增强MRI后,可比较齿状核-脑桥信号强度比从首次到末次检查的变化。
- 报告时可将齿状核T1加权信号增高与累积钆剂量关联考虑。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To determine whether repeated gadolinium-based contrast agent administration (GBCA) in children is associated with the development of increased T1-weighted signal intensity within the cerebellar dentate nucleus.
MATERIALS AND METHODS: With institutional review board approval for this The Health Insurance Portability and Accountability Act-compliant retrospective study, a cohort of 41 patients under the age of 18 years who underwent at least four contrast-enhanced magnetic resonance imaging (MR) examinations of the brain from 2005 to 2015 were identified. For each examination, both dentate nuclei were manually contoured, and the mean dentate nucleus-to-pons signal intensity (DN-P SI) ratio was calculated. The DN-P SI ratios from the last to first MRI examination were compared, and the correlation between DN-P SI ratio and cumulative gadolinium dose was calculated using a linear mixed effect model to control for potentially confounding variables.
RESULTS: For the 41 patients in the cohort, there was a significant increase in the mean DN-P SI ratio from the first MRI to the last MRI examination (1.05 versus 1.11, p=0.004). After controlling for patient diagnosis, history of chemotherapy or radiation, sex, and age, there was a significant positive association between DN-P SI ratio and cumulative gadolinium dose (coefficient=0.401, p=0.032).
CONCLUSION: Repeated GBCA administration in children is associated with increased T1-weighted signal intensity within the dentate nucleus.
引用
- Young JR, Orosz I, Franke MA, et al. Gadolinium deposition in the paediatric brain: T1-weighted hyperintensity within the dentate nucleus following repeated gadolinium-based contrast agent administration. Clin Radiol. 2017. PMID: 29208312. doi:10.1016/j.crad.2017.11.005