CTA与MRI/MRA在评估颅内硬脑膜动静脉瘘皮层静脉反流中的诊断准确性
本研究回顾性分析108例血管造影确诊的颅内硬脑膜动静脉瘘患者,比较CTA与MRI/MRA检测皮层静脉反流的诊断准确性。CTA各征象敏感度62%~96%、特异度79%~94%,MRI/MRA各征象敏感度58%~83%、特异度77%~93%。CTA与MRI/MRA的ROC曲线下面积分别为0.91和0.87(直接比较P=0.04),CTA对高级别病变(P=0.05)和非侵袭性表现(P=0.04)诊断准确性更优。
要点
- CTA与MRI/MRA对颅内DAVF皮层静脉反流均有良好诊断准确性。
- CTA的AUC为0.91,高于MRI/MRA的0.87(P=0.04)。
- CTA对高级别病变及非侵袭性表现诊断准确性更优(P=0.05和P=0.04)。
核心结论
- CTA和MRI/MRA对颅内DAVF患者皮层静脉反流的检测均具有良好诊断准确性,有适度证据表明CTA优于MRI/MRA。
研究设计与样本
- 回顾性分析2008年1月至2016年7月经血管造影确诊的颅内DAVF患者,纳入同时接受CTA和MRI/MRA检查者共108例,以血管造影为参考标准。
关键影像表现/征象
- CTA的皮层静脉反流征象包括异常扩张、早期强化以及存在髓静脉或软脑膜静脉。
- MRI/MRA的皮层静脉反流征象包括异常扩张、早期强化、血流相关强化、流空影以及髓静脉或软脑膜静脉侧支。
诊断标准与关键数值
- CTA各征象敏感度范围为62%~96%,特异度范围为79%~94%。
- MRI/MRA各征象敏感度范围为58%~83%,特异度范围为77%~93%。
- CTA与MRI/MRA的ROC曲线下面积分别为0.91和0.87(直接比较P=0.04)。
- 亚组分析中CTA对更高级别病变诊断准确性更好(P=0.05),对非侵袭性表现诊断准确性更好(P=0.04)。
临床应用与阅片要点
- CTA和MRI/MRA均可用于检测颅内DAVF的皮层静脉反流征象。
- 有适度证据表明CTA在检测皮层静脉反流方面优于MRI/MRA。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Computed tomography angiography (CTA) and magnetic resonance imaging/angiography (MRI/MRA) are used for the diagnosis of intracranial dural arteriovenous fistulas (DAVFs). The purpose of this study was to compare the diagnostic accuracy of CTA and magnetic resonance imaging/angiography (MRI/MRA) for detection of cortical venous reflux (CVR) in intracranial DAVFs.
METHODS: The records of patients with angiography-confirmed intracranial DAVFs who also received CTA and MRI/MRA from January 2008 to July 2016 were reviewed. CTA and MRI/MRA were reviewed for signs of CVR, and the diagnostic accuracy of individual signs was evaluated by receiver operating curve (ROC) analysis.
RESULTS: A total 108 patients were included in this study. CTA signs of CVR included abnormal dilatation, early enhancement, and the presence of a medullary or pial vein. MRI/MRA signs of CVR included abnormal dilatation, early enhancement, flow-related enhancement, flow void, and medullary or pial venous collaterals. The sensitivity of individual CTA signs ranged from 62 to 96%, and specificities from 79 to 94%. The sensitivities of individual MRI/MRA signs ranged from 58 to 83%, and specificities from 77 to 93%. The area under ROC curve (AUC) of CTA and MRI/MRA were 0.91 and 0.87, respectively (P = 0.04 in direct comparison). In subgroup analysis, CTA had better diagnostic accuracy for higher grade disease (P = 0.05) and non-aggressive manifestation (P = 0.04).
CONCLUSIONS: Both CTA and MRI/MRA have good diagnostic accuracy for detection of CVR in patients with intracranial DAVFs. There is modest evidence that CTA is better than MRI/MRA.
引用
- Lin YH, Wang YF, Liu HM, et al. Diagnostic accuracy of CTA and MRI/MRA in the evaluation of the cortical venous reflux in the intracranial dural arteriovenous fistula DAVF. Neuroradiology. 2017. PMID: 29188304. doi:10.1007/s00234-017-1948-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。