文献速递神经PET

11C-蛋氨酸PET鉴别原发性低级别与高级别胶质瘤:双变量诊断试验准确性Meta分析

Discrimination between primary low-grade and high-grade glioma with 11C-methionine PET: a bivariate diagnostic test accuracy meta-analysis.
PubMed 文献 · Br J Radiol · 2018-01-22

该系统评价共纳入13项研究、241例患者,评估11C-蛋氨酸PET术前鉴别原发性低级别与高级别胶质瘤的诊断准确性。双变量随机效应模型显示,合并敏感度为0.80(95%CI 0.66-0.88),假阳性率为0.28(95%CI 0.19-0.38),双变量汇总ROC曲线下面积为0.78,相对MET摄取最佳临界值为2.21。作者认为MET PET具有中等偏高的诊断准确性,可作为无创鉴别LGG与HGG的临床工具。

要点

  • MET PET鉴别LGG与HGG的汇总敏感度为0.80(95%CI 0.66-0.88),汇总假阳性率为0.28(95%CI 0.19-0.38)。
  • 双变量汇总ROC曲线下面积为0.78,相对MET摄取最佳临界值为2.21。
  • 异质性来源包括患者纳入偏倚、研究质量和比值方法。

核心结论

  • MET PET对原发性LGG与HGG的鉴别具有中等偏高的诊断准确性,在临界值2.21时可作为无创鉴别工具。

研究设计与样本

  • 系统评价与双变量诊断准确性Meta分析,检索截至2016年11月7日,最终纳入13项研究共241例患者,提取术前MET PET相对摄取与术后神经病理诊断(星形细胞瘤或少突胶质细胞瘤)的个体患者数据。

诊断标准与关键数值

  • MET PET鉴别LGG与HGG的双变量汇总ROC曲线下面积为0.78,汇总敏感度为0.80(95%CI 0.66-0.88),汇总假阳性率为0.28(95%CI 0.19-0.38),相对MET摄取最佳临界值为2.21。

临床应用与阅片要点

  • 作者认为MET PET可作为无创鉴别LGG与HGG的临床工具,在相对MET摄取临界值2.21时具有中等偏高的诊断准确性。

局限性

  • 异质性来源包括患者纳入偏倚、研究质量和比值方法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To perform a meta-analysis evaluating the diagnostic accuracy of 11C-methionine (MET) positron emission tomography (PET) to discriminate between primary low-grade glioma (LGG) and high-grade glioma (HGG).

METHODS: A systematic database search was performed by a librarian in relevant databases with the latest search on 07 November 2016. Hits were assessed for inclusion independently by two authors. Individual patient data on relative MET uptake was extracted on patients examined pre-operatively with MET PET and subsequent neuropathological diagnosis of astrocytoma or oligodendroglioma. Individual patient data were analysed for diagnostic accuracy using a bivariate diagnostic random-effects meta-analysis model with restricted maximum likelihood estimation method. Bivariate meta-regression and subgroup analyses assessed study heterogeneity and validity. This study is registered with PROSPERO, number CRD42016050747.

RESULTS: Out of 1828 hits, 13 studies comprising of 241 individuals were included in the quantitative and qualitative analysis. MET PET had an area under the bivariate summary receiver operating characteristics curve of 0.78 to discriminate between LGG and HGG and a summary sensitivity of 0.80 with 95% confidence interval (CI) (0.66-0.88) and a summary false positive rate of 0.28, 95% CI (0.19-0.38). Heterogeneity was described by; bias in patient inclusion, study quality, and ratio method. Optimal cutoff for relative MET uptake was 2.21.

CONCLUSION: MET PET had a moderately high diagnostic accuracy for the discrimination between primary LGG and HGG. Advances in knowledge: MET PET can be used as a clinical tool for the non-invasive discrimination between LGG and HGG with a moderately high accuracy at cut-off 2.21.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Falk Delgado A, Falk Delgado A. Discrimination between primary low-grade and high-grade glioma with 11C-methionine PET: a bivariate diagnostic test accuracy meta-analysis. Br J Radiol. 2018. PMID: 29206062. doi:10.1259/bjr.20170426

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。