文献速递神经CT

基于计算机断层扫描的缺血性脑病灶体素级水摄取成像:密度与直接容积测量之间的关系

Computed Tomography-Based Imaging of Voxel-Wise Lesion Water Uptake in Ischemic Brain: Relationship Between Density and Direct Volumetry.
PubMed 文献 · Invest Radiol · 2018-01-01

研究建立并验证CT密度降低与缺血病灶净水摄取之间的线性理论关系,体外碘溶液实验显示密度法水摄取与直接容积测量等效(r=0.99),回顾性多中心50个水肿性梗死灶中密度法百分比水摄取为21.4%±6.4%,与直接容积法22.7%±7.4%差异无统计学显著(P<0.0001)。

要点

  • CT密度降低可定量计算梗死灶净水摄取,密度法与直接容积法差异无统计学显著。
  • 体外实验显示密度法水摄取与直接容积测量高度相关(r=0.99,P<0.0001)。
  • 体素级水摄取成像可反映病灶病理生理,可能作为急性梗死灶的定量影像生物标志物。

核心结论

  • 梗死灶水摄取容积可通过相对CT密度测量定量计算,体素级水摄取成像描绘病灶病理生理,可能作为急性梗死灶的定量影像生物标志物。

研究设计与样本

  • 研究建立CT密度降低与净水摄取的理论线性关系,采用体外递进稀释碘溶液连续CT测量验证,并在回顾性多中心队列的50个水肿性梗死灶中,以缺血与正常半球容积差直接测量为参考,与密度法计算值相关分析。

诊断标准与关键数值

  • 体外密度法水摄取与直接容积测量等效(r=0.99,P<0.0001;平均±标准差差值-0.29%±0.39%,与0无差异,P<0.0001);队列中直接容积法病灶平均水摄取44.7±26.8 mL,病灶体积平均百分比水摄取22.7%±7.4%,密度法百分比水摄取21.4%±6.4%,两者平均差值-1.79%±3.40%,与0无显著差异(P<0.0001)。

局限性

  • 原文为回顾性多中心队列。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Net water uptake per volume of brain tissue may be calculated by computed tomography (CT) density, and this imaging biomarker has recently been investigated as a predictor of lesion age in acute stroke. However, the hypothesis that measurements of CT density may be used to quantify net water uptake per volume of infarct lesion has not been validated by direct volumetric measurements so far. The purpose of this study was to (1) develop a theoretical relationship between CT density reduction and net water uptake per volume of ischemic lesions and (2) confirm this relationship by quantitative in vitro and in vivo CT image analysis using direct volumetric measurements.

MATERIALS AND METHODS: We developed a theoretical rationale for a linear relationship between net water uptake per volume of ischemic lesions and CT attenuation. The derived relationship between water uptake and CT density was tested in vitro in a set of increasingly diluted iodine solutions with successive CT measurements. Furthermore, the consistency of this relationship was evaluated using human in vivo CT images in a retrospective multicentric cohort. In 50 edematous infarct lesions, net water uptake was determined by direct measurement of the volumetric difference between the ischemic and normal hemisphere and was correlated with net water uptake calculated by ischemic density measurements.

RESULTS: With regard to in vitro data, water uptake by density measurement was equivalent to direct volumetric measurement (r = 0.99, P < 0.0001; mean ± SD difference, -0.29% ± 0.39%, not different from 0, P < 0.0001). In the study cohort, the mean ± SD uptake of water within infarct measured by volumetry was 44.7 ± 26.8 mL and the mean percent water uptake per lesion volume was 22.7% ± 7.4%. This was equivalent to percent water uptake obtained from density measurements: 21.4% ± 6.4%. The mean difference between percent water uptake by direct volumetry and percent water uptake by CT density was -1.79% ± 3.40%, which was not significantly different from 0 (P < 0.0001).

CONCLUSIONS: Volume of water uptake in infarct lesions can be calculated quantitatively by relative CT density measurements. Voxel-wise imaging of water uptake depicts lesion pathophysiology and could serve as a quantitative imaging biomarker of acute infarct lesions.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Broocks G, Flottmann F, Ernst M, et al. Computed Tomography-Based Imaging of Voxel-Wise Lesion Water Uptake in Ischemic Brain: Relationship Between Density and Direct Volumetry. Invest Radiol. 2018. PMID: 29200013. doi:10.1097/RLI.0000000000000430

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。