磁共振扩散峰度成像鉴别脑胶质瘤分级:诊断准确性的Meta分析
该系统评价纳入10项研究共430例患者,评估扩散峰度成像的平均峰度(MK)鉴别低级别胶质瘤(WHO II级)与高级别胶质瘤(WHO III或IV级)的诊断准确性。低级别与高级别胶质瘤间MK平均差异为0.17(95%CI:0.11,0.22),汇总AUC为0.94,敏感度0.85(95%CI:0.74,0.92),特异度0.92(95%CI:0.81,0.96)。作者结论为MK在鉴别低级别与高级别胶质瘤中显示高诊断准确性。
要点
- MK鉴别低级别与高级别胶质瘤的汇总AUC为0.94,敏感度0.85,特异度0.92。
- 低级别与高级别胶质瘤间MK平均差异为0.17(95%CI:0.11,0.22;P<.001)。
- 异质性来源包括胶质瘤亚型、回波时间、复发与原发性胶质瘤比例及DKI技术。
核心结论
- MK在鉴别低级别胶质瘤与高级别胶质瘤中显示高诊断准确性。
研究设计与样本
- 系统检索Cochrane Library、Embase、Medline和Web of Science核心合集,由两名馆员完成检索。
- 纳入10项研究共430例患者,由两名研究者采用QUADAS-2工具评价纳入研究质量。
- 采用随机效应模型分析低级别与高级别胶质瘤间MK均值的差异,并行异质性分析。
- 采用双变量限制性最大似然估计法描述汇总受试者工作特征曲线并行双变量Meta回归。
诊断标准与关键数值
- 低级别与高级别胶质瘤间MK平均差异为0.17(95%CI:0.11,0.22),z=5.86(P<.001)。
- 鉴别高级别与低级别胶质瘤的汇总AUC为0.94,敏感度0.85(95%CI:0.74,0.92),特异度0.92(95%CI:0.81,0.96)。
- 统计异质性可由胶质瘤亚型、回波时间及复发胶质瘤与原发性胶质瘤的比例解释。
- 异质性由神经病理亚型和DKI技术驱动。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 异质性由神经病理亚型和DKI技术驱动,统计异质性可由胶质瘤亚型、回波时间及复发与原发性胶质瘤比例解释。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To assess the diagnostic test accuracy and sources of heterogeneity for the discriminative potential of diffusion kurtosis imaging (DKI) to differentiate low-grade glioma (LGG) (World Health Organization [WHO] grade II) from high-grade glioma (HGG) (WHO grade III or IV). Materials and Methods The Cochrane Library, Embase, Medline, and the Web of Science Core Collection were systematically searched by two librarians. Retrieved hits were screened for inclusion and were evaluated with the revised tool for quality assessment for diagnostic accuracy studies (commonly known as QUADAS-2) by two researchers. Statistical analysis comprised a random-effects model with associated heterogeneity analysis for mean differences in mean kurtosis (MK) in patients with LGG or HGG. A bivariate restricted maximum likelihood estimation method was used to describe the summary receiver operating characteristics curve and bivariate meta-regression. Results Ten studies involving 430 patients were included. The mean difference in MK between LGG and HGG was 0.17 (95% confidence interval [CI]: 0.11, 0.22) with a z score equal to 5.86 (P < .001). The statistical heterogeneity was explained by glioma subtype, echo time, and the proportion of recurrent glioma versus primary glioma. The pooled area under the curve was 0.94 for discrimination of HGG from LGG, with 0.85 (95% CI: 0.74, 0.92) sensitivity and 0.92 (95% CI: 0.81, 0.96) specificity. Heterogeneity was driven by neuropathologic subtype and DKI technique. Conclusion MK shows high diagnostic accuracy in the discrimination of LGG from HGG. © RSNA, 2017 Online supplemental material is available for this article.
引用
- Falk Delgado A, Nilsson M, van Westen D, et al. Glioma Grade Discrimination with MR Diffusion Kurtosis Imaging: A Meta-Analysis of Diagnostic Accuracy. Radiology. 2017. PMID: 29206593. doi:10.1148/radiol.2017171315
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。