文献速递神经技术与安全MR

利用深度学习改进动脉自旋标记成像

Improving Arterial Spin Labeling by Using Deep Learning.
PubMed 文献 · Radiology · 2017-12-21

研究采用卷积神经网络从较少的成对减影图像生成动脉自旋标记灌注图像,以六或七幅减影图像平均作为参考标准,在健康受试者和患者数据中均显示均方误差较传统平均法降低约40%,并在卒中数据集测试中表现更优。

要点

  • 卷积神经网络可从两到三幅减影图像生成动脉自旋标记灌注图像,减少采集次数需求。
  • 在健康受试者、患者及卒中测试集中,均方误差较传统平均法降低约40%(P < .001)。
  • 放射学评分显示卷积神经网络对噪声、运动及分割伪影的抑制优于传统平均法(P < .001)。

核心结论

  • 卷积神经网络在从成对减影图像生成动脉自旋标记图像时,较传统平均法提供更优的灌注图像质量和更准确的灌注测量。

研究设计与样本

  • 采用卷积神经网络作为深度学习算法从成对减影生成动脉自旋标记图像,参考标准由六或七幅成对减影图像平均生成,数据来自7名健康受试者的常规伪连续动脉自旋标记和114例各类疾病患者的哈达玛编码伪连续动脉自旋标记,训练网络从两到三幅减影图像生成灌注图像并进行交叉验证,患者数据集训练的网络另在26个独立卒中数据集上测试。

关键影像表现/征象

  • 卷积神经网络生成的脑血流量图在卒中感兴趣区分析中均方误差为19.7 mL/100 g/min ± 9.7,低于传统平均法的43.2 ± 29.8(P < .001)。
  • 放射学评分显示卷积神经网络对噪声、运动及分割伪影的抑制优于传统平均法(P < .001)。

诊断标准与关键数值

  • 在健康受试者和患者的交叉验证及独立卒中患者测试中,均方误差较传统平均法降低约40%(P < .001)。
  • 卒中区域感兴趣区分析中,卷积神经网络脑血流量图均方误差为19.7 mL/100 g/min ± 9.7,传统平均法为43.2 ± 29.8(P < .001)。

临床应用与阅片要点

  • 卷积神经网络可从较少(两到三幅)成对减影图像生成灌注图像,可能有助于减少动脉自旋标记采集时间或减影帧数。
  • 卷积神经网络生成的图像在噪声、运动及分割伪影抑制方面表现优于传统平均法,阅片时可能减少相关伪影干扰。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To develop a deep learning algorithm that generates arterial spin labeling (ASL) perfusion images with higher accuracy and robustness by using a smaller number of subtraction images. Materials and Methods For ASL image generation from pair-wise subtraction, we used a convolutional neural network (CNN) as a deep learning algorithm. The ground truth perfusion images were generated by averaging six or seven pairwise subtraction images acquired with (a) conventional pseudocontinuous arterial spin labeling from seven healthy subjects or (b) Hadamard-encoded pseudocontinuous ASL from 114 patients with various diseases. CNNs were trained to generate perfusion images from a smaller number (two or three) of subtraction images and evaluated by means of cross-validation. CNNs from the patient data sets were also tested on 26 separate stroke data sets. CNNs were compared with the conventional averaging method in terms of mean square error and radiologic score by using a paired t test and/or Wilcoxon signed-rank test. Results Mean square errors were approximately 40% lower than those of the conventional averaging method for the cross-validation with the healthy subjects and patients and the separate test with the patients who had experienced a stroke (P < .001). Region-of-interest analysis in stroke regions showed that cerebral blood flow maps from CNN (mean ± standard deviation, 19.7 mL per 100 g/min ± 9.7) had smaller mean square errors than those determined with the conventional averaging method (43.2 ± 29.8) (P < .001). Radiologic scoring demonstrated that CNNs suppressed noise and motion and/or segmentation artifacts better than the conventional averaging method did (P < .001). Conclusion CNNs provided superior perfusion image quality and more accurate perfusion measurement compared with those of the conventional averaging method for generation of ASL images from pair-wise subtraction images. © RSNA, 2017.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Kim KH, Choi SH, Park SH, et al. Improving Arterial Spin Labeling by Using Deep Learning. Radiology. 2017. PMID: 29267145. doi:10.1148/radiol.2017171154

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。