锥形束CT引导经椎间孔鞘内注射诺西那生钠治疗伴广泛脊柱内固定的脊髓性肌萎缩症儿童:技术成功与安全性的早期结果

Transforaminal intrathecal delivery of nusinersen using cone-beam computed tomography for children with spinal muscular atrophy and extensive surgical instrumentation: early results of technical success and safety.
PubMed 文献 · Pediatr Radiol · 2017-11-13

本研究回顾性分析4例伴广泛脊柱内固定、无法行标准后路腰椎穿刺的脊髓性肌萎缩症儿童,共15次经椎间孔鞘内注射诺西那生钠,采用锥形束CT联合双轴透视导航 overlay 引导。所有操作技术成功,无主要并发症,1例次轻微并发症为术后神经病理性头痛,平均透视时间1.9分钟,空气比释动能55.8 mGy。作者认为该方法安全有效。

要点

  • 对脊柱内固定和畸形致标准后路穿刺困难的SMA儿童,锥形束CT导航下经椎间孔入路可实现鞘内注射。
  • 15例次操作均技术成功,无主要并发症,1例次术后神经病理性头痛经加巴喷丁治愈。
  • 平均透视时间1.9分钟,空气比释动能55.8 mGy。

核心结论

  • 锥形束CT联合双轴透视导航 overlay 是伴脊柱畸形和内固定、无法采用标准技术的儿童经椎间孔鞘内入路的安全有效方法。

研究设计与样本

  • 回顾性综述,纳入4例伴广泛脊柱内固定、无法行标准后路腰椎穿刺的SMA儿童,共15次连续诺西那生钠注射,采用锥形束CT联合导航 overlay 引导经椎间孔鞘内入路,分析技术成功、并发症和总透视时间。

临床应用与阅片要点

  • 对脊柱内固定和畸形致标准后路腰椎穿刺困难的SMA儿童,可采用锥形束CT联合双轴透视导航 overlay 引导经椎间孔鞘内入路。
  • 术后神经病理性头痛可能与操作体位相关,原文报告经加巴喷丁治疗成功。

局限性

  • 原文标题和摘要中明确为早期结果。
  • 原文为回顾性综述。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Nusinersen, the only treatment approved by the United States Food and Drug Administration for spinal muscular atrophy (SMA), is delivered intrathecally. Many children with SMA have extensive spinal instrumentation and deformities, often precluding the use of standard approaches for gaining intrathecal access. Furthermore the anatomical distortion that often occurs with rotoscoliosis can complicate the use of fluoroscopic guidance. Compared to fluoroscopy, CT affords superior guidance for complex needle placements. This opens up alternatives to the posterior (interlaminar) technique, including transforaminal and caudal approaches.

OBJECTIVE: This study describes the early results of technical success, complications and radiation dose of intrathecal delivery of nusinersen using cone-beam CT guidance with two-axis fluoroscopic navigational overlay.

MATERIALS AND METHODS: We conducted a retrospective review of 15 consecutive nusinersen injections performed in four children with SMA and extensive spinal hardware precluding standard posterior lumbar puncture techniques. These children were treated using transforaminal thecal access employing cone-beam CT with navigational overlay. We analyzed results including technical success, complications and total fluoroscopy time.

RESULTS: All procedures were technically successful. No major complications and one minor complication were reported; the minor complication was a post-procedural neuropathic headache that was attributed to procedural positioning and was treated successfully with gabapentin. The average procedural fluoroscopy time and air kerma were 1.9 min and 55.8 mGy, respectively.

CONCLUSION: Cone-beam CT guidance with two-axis navigational overlay is a safe, effective method for gaining transforaminal intrathecal access in children with spinal abnormalities and hardware precluding the use of standard techniques.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Weaver JJ, Natarajan N, Shaw DWW, et al. Transforaminal intrathecal delivery of nusinersen using cone-beam computed tomography for children with spinal muscular atrophy and extensive surgical instrumentation: early results of technical success and safety. Pediatr Radiol. 2017. PMID: 29130140. doi:10.1007/s00247-017-4031-6