文献速递儿科影像骨肌DR

儿童下肢测量中微剂量双平面X线摄影的评估

Assessment of micro-dose biplanar radiography in lower limb measurements in children.
PubMed 文献 · Eur Radiol · 2017-11-21

微剂量方案下长度测量一致性均>0.90,膝内外翻和屈曲/过伸偏差一致性为0.75-0.90(M1型)和>0.90(M2、M3型),交付剂量和吸收剂量分别降低至8.5倍和5.4倍。作者认为微剂量可用于儿童下肢对线测量并显著降低剂量。

要点

  • 儿童下肢长度测量在微剂量双平面X线摄影下观察者间和观察者内一致性均>0.90。
  • 膝内外翻和屈曲/过伸偏差在M2、M3型儿童中一致性>0.90,M1型为0.75-0.90。
  • 微剂量方案使交付剂量降低8.5倍、吸收剂量降低5.4倍。

核心结论

  • 微剂量双平面X线摄影可用于儿童下肢对线测量,并实现交付剂量和吸收剂量的显著降低。

研究设计与样本

  • 研究纳入6岁以上儿童,按髋宽分为M1(<25 cm)、M2(25-35 cm)、M3(>35 cm)三种体型,交替使用微剂量与低剂量双平面X线摄影方案,同时采集正位和侧位图像,由两名独立观察者进行下肢对线测量(n=526),每种体型15名儿童由第三名观察者重复测量两次(n=180)。

诊断标准与关键数值

  • 微剂量方案下,长度测量的观察者间和观察者内一致性系数均>0.90(各体型);膝内外翻和屈曲/过伸偏差的观察者间和观察者内一致性系数在M1型为0.75-0.90,在M2和M3型>0.90;交付剂量降低8.5倍,吸收剂量降低5.4倍。

临床应用与阅片要点

  • 作者认为微剂量双平面X线摄影可用于儿童下肢对线测量,并显著降低交付剂量和吸收剂量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate in children microdose protocol compared with low dose for lower limb alignment (LLA) measurements on biplanar radiography.

METHODS: Children 6 years or older were included. Height, weight and hip width were measured prior to imaging. Hip width allowed classifying children into morphotype M1 (width <25 cm), M2 (25-35 cm) or M3 (>35 cm) corresponding to predefined acquisition parameters (kV, mA, tube speed). Micro- and low-dose protocols were used alternately, with simultaneous acquisition of frontal and lateral radiographs. LLA measurements were performed by two independent observers (n = 526). In 15 children per morphotype, a third observer performed measurements twice (n = 180). Intraclass correlation coefficients and the dose (delivered, absorbed) were calculated.

RESULTS: 100 girls and 160 boys (mean age = 11.7 years) were investigated: 74 M1 (mean BMI, 15.7kg/m2), 149 M2 (19.8 kg/m2) and 40 M3 (30.2 kg/m2). With microdose, inter- and intra-observer agreement was >0.90 for lengths whatever the morphotype, 0.75-0.90 (M1) and >0.90 (M2, M3) for valgus/varus and flexion/hyperextension deviations. Dose reduction reached a factor of 8.5 and 5.4 for the delivered and absorbed dose respectively.

CONCLUSIONS: Microdose could be used for LLA measurements in children and permits a significant dose reduction.

KEY POINTS: • Lower limb lengths of children can be evaluated with microdose biplanar radiography. • Valgus/varus deviations also can be evaluated with microdose biplanar radiography. • Microdose biplanar radiography significantly reduces delivered and absorbed dose in children.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Lerisson H, Amzallag-Bellenger É, Cebulski-Delebarre A, et al. Assessment of micro-dose biplanar radiography in lower limb measurements in children. Eur Radiol. 2017. PMID: 29164381. doi:10.1007/s00330-017-5144-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。