文献速递儿科影像技术与安全US

校正颈动脉血流时间检测腹泻儿童脱水的性能

Carotid Flow Time Test Performance for the Detection of Dehydration in Children With Diarrhea.
PubMed 文献 · J Ultrasound Med · 2017-11-09

在孟加拉国达卡招募350例0-60月龄急性腹泻儿童,就诊时测量校正颈动脉血流时间,以补液后体重变化百分比将脱水分为重度(>9%)、部分(3%-9%)和无(<3%);校正颈动脉血流时间检测重度脱水的AUC为0.51(95%CI 0.42-0.61),线性回归显示血流时间与脱水程度关联微弱,结论为该指标在此人群中对重度脱水预测能力差。

要点

  • 校正颈动脉血流时间检测重度脱水AUC仅0.51,对腹泻儿童脱水预测能力差。
  • 以补液后体重变化百分比为参考标准,将脱水分为重度>9%、部分3%-9%、无<3%。
  • 校正颈动脉血流时间与脱水程度仅呈弱关联,不宜作为该人群脱水评估依据。

核心结论

  • 校正颈动脉血流时间在此腹泻儿童人群中对重度脱水预测能力差,AUC为0.51(95%CI 0.42-0.61)。

研究设计与样本

  • 前瞻性招募急性腹泻儿童,按医院方案补液,就诊时测量校正颈动脉血流时间,以补液后体重变化百分比为参考标准,共纳入350例0-60月龄儿童。

关键影像表现/征象

  • 校正颈动脉血流时间均值为326毫秒(四分位距295-351毫秒)。

诊断标准与关键数值

  • 重度脱水定义为补液后体重变化>9%,部分脱水为3%-9%,无脱水为<3%。
  • 校正颈动脉血流时间检测重度脱水的AUC为0.51(95%CI 0.42-0.61)。
  • 线性回归显示校正颈动脉血流时间与脱水百分比之间关联微弱。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Unstructured clinical assessments of dehydration in children are inaccurate. Point-of-care ultrasound is a noninvasive diagnostic tool that can help evaluate the volume status; the corrected carotid artery flow time has been shown to predict volume depletion in adults. We sought to determine the ability of the corrected carotid artery flow time to identify dehydration in a population of children presenting with acute diarrhea in Dhaka, Bangladesh.

METHODS: Children presenting with acute diarrhea were recruited and rehydrated according to hospital protocols. The corrected carotid artery flow time was measured at the time of presentation. The percentage of weight change with rehydration was used to categorize each child's dehydration as severe (>9%), some (3%-9%), or none (<3%). A receiver operating characteristic curve was constructed to test the performance of the corrected carotid artery flow time for detecting severe dehydration. Linear regression was used to model the relationship between the corrected carotid artery flow time and percentage of dehydration.

RESULTS: A total of 350 children (0-60 months) were enrolled. The mean corrected carotid artery flow time was 326 milliseconds (interquartile range, 295-351 milliseconds). The area under the receiver operating characteristic curve for the detection of severe dehydration was 0.51 (95% confidence interval, 0.42, 0.61). Linear regression modeling showed a weak association between the flow time and dehydration.

CONCLUSIONS: The corrected carotid artery flow time was a poor predictor of severe dehydration in this population of children with diarrhea.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Mackenzie DC, Nasrin S, Atika B, et al. Carotid Flow Time Test Performance for the Detection of Dehydration in Children With Diarrhea. J Ultrasound Med. 2017. PMID: 29119578. doi:10.1002/jum.14478

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。