文献速递骨肌神经CTMR

低剂量与超低剂量CT对下腰痛患者腰椎间盘疾病和小关节骨关节炎的诊断准确性:与MRI对照

Diagnostic accuracy of low-dose versus ultra-low-dose CT for lumbar disc disease and facet joint osteoarthritis in patients with low back pain with MRI correlation.
PubMed 文献 · Skeletal Radiol · 2017-11-06

前瞻性纳入260例慢性下腰痛患者,分别行低剂量(LD,n=143)与超低剂量(ULD,n=117)腰椎CT迭代重建,以MRI共识诊断为参考标准。BMI<25 kg/m²组中ULD与LD诊断准确性相似(敏感度95.1-98.1% vs 95.6-100%,特异度92.5-98.7% vs 95.5-98.9%,准确率94.6-98.0% vs 97.4-98.1%,均p≥0.1),ULD剂量降低60-68%;BMI3组ULD定性图像质量较低。

要点

  • BMI<25 kg/m²患者中,超低剂量CT诊断腰椎间盘疾病和小关节骨关节炎的准确性似与低剂量CT相当。
  • 超低剂量方案辐射剂量较标准低剂量方案降低60-68%。
  • BMI≥25 kg/m²患者超低剂量CT定性图像质量较低,阅片需注意。

核心结论

  • 对于BMI<25 kg/m²的慢性下腰痛患者,超低剂量腰椎CT迭代重建图像质量可接受,诊断准确性似与低剂量CT相似,作者认为其是有用的诊断工具。

研究设计与样本

  • 前瞻性研究,2015年11月至2016年9月纳入260例慢性下腰痛患者,143例行低剂量CT迭代重建、117例行超低剂量CT迭代重建,按BMI分为BMI1(<22.9 kg/m²)、BMI2(23.0-24.9 kg/m²)、BMI3(≥25 kg/m²)三组,以MRI共识诊断为参考标准,两名放射科医师盲法独立评估。

关键影像表现/征象

  • 超低剂量方案在所有患者中信噪比显著降低(p<0.001),椎体除外。
  • BMI3组超低剂量方案定性图像质量较低(p≤0.033)。
  • 图像质量与最终诊断的观察者间一致性为优或良。

诊断标准与关键数值

  • BMI1和BMI2组:超低剂量敏感度95.1-98.1%、特异度92.5-98.7%、准确率94.6-98.0%。
  • BMI1和BMI2组:低剂量敏感度95.6-100%、特异度95.5-98.9%、准确率97.4-98.1%。
  • BMI1和BMI2组超低剂量与低剂量诊断性能差异均无统计学意义(均p≥0.1)。
  • 超低剂量方案辐射剂量较低剂量方案降低60-68%。

临床应用与阅片要点

  • BMI<25 kg/m²的慢性下腰痛患者行腰椎CT时,超低剂量迭代重建方案可提供与低剂量方案相似的诊断准确性。
  • BMI≥25 kg/m²患者超低剂量CT定性图像质量较低,阅片时需结合图像质量评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the image quality, radiation dose, and diagnostic performance between low-dose (LD) and ultra-low-dose (ULD) lumbar-spine (L-spine) CT with iterative reconstruction (IR) for patients with chronic low back pain (LBP).

METHODS: In total, 260 patients with chronic LBP who underwent L-spine CT between November 2015 and September 2016 were prospectively enrolled. Of these, 143 underwent LD-CT with IR and 117 underwent ULD-CT with IR. The patients were divided according to their body mass index (BMI) into BMI1 (<22.9 kg/m2), BMI2 (23.0-24.9 kg/m2), and BMI3 (≥25 kg/m2) groups. Two blinded radiologists independently evaluated the signal-to-noise ratio (SNR), qualitative image quality, and final diagnoses (lumbar disc disease and facet joint osteoarthritis). L-spine MRIs interpreted by consensus were used as the reference standard. All data were statistically analyzed.

RESULTS: ULD protocol showed significantly lower SNR for all patients (p < 0.001) except the vertebral bodies and lower qualitative image quality for BMI3 patients (p ≤ 0.033). There was no statistically significant difference between ULD (sensitivity, 95.1-98.1%; specificity, 92.5-98.7%; accuracy, 94.6-98.0%) and LD protocols (sensitivity, 95.6-100%; specificity, 95.5-98.9%; accuracy, 97.4-98.1%), (all p≥0.1) in the BMI1 and BMI2; while dose was 60-68% lower with the ULD protocol. Interobserver agreements were excellent or good with regard to image quality and final diagnoses.

CONCLUSIONS: For the BM1 and BMI2 groups, ULD-CT provided an acceptable image quality and exhibited a diagnostic accuracy similar to that of LD-CT. These findings suggest that it is a useful diagnostic tool for patients with chronic LBP who exhibit a BMI of <25 kg/m2.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Lee SH, Yun SJ, Jo HH, et al. Diagnostic accuracy of low-dose versus ultra-low-dose CT for lumbar disc disease and facet joint osteoarthritis in patients with low back pain with MRI correlation. Skeletal Radiol. 2017. PMID: 29110049. doi:10.1007/s00256-017-2811-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。