文献速递骨肌MR

3T 体素内不相干运动扩散加权 MRI 鉴别良恶性肌肉骨骼肿瘤

Intravoxel incoherent motion diffusion-weighted MR imaging for differentiation of benign and malignant musculoskeletal tumours at 3 T.
PubMed 文献 · Br J Radiol · 2017-12-15

回顾性纳入 65 例未经治疗的肌肉骨骼肿瘤患者(恶性 47 例、良性 23 例),在 3T 下行体素内不相干运动扩散加权成像。恶性肿瘤的纯扩散系数 D 和表观扩散系数 ADC 显著低于良性肿瘤,灌注分数 f 显著高于良性肿瘤,假扩散系数 D* 无显著差异。D 与 ADC 的鉴别效能优于 f 和 D*,D 与 ADC 之间无显著差异。

要点

  • 恶性肿瘤 D 值(923 ± 360 µm²/s)和 ADC 值(965 ± 353 µm²/s)显著低于良性肿瘤(分别为 1668 ± 546、1689 ± 526 µm²/s)(p < 0.001)。
  • D 和 ADC 取 cut-off 值 1200 µm²/s 时,敏感度分别为 92%、92%,特异度分别为 83%、87%,准确率分别为 89%、90%。
  • D、ADC 和 f 的 ROC 曲线下面积分别为 0.874、0.880 和 0.671;D* 在良恶性肿瘤间无显著差异(p > 0.05)。

核心结论

  • 在 3T 体素内不相干运动扩散加权成像中,D 和 ADC 鉴别恶性与良性肌肉骨骼肿瘤可能比 f 和 D* 更准确可靠,D 与 ADC 的诊断效能无显著差异。

研究设计与样本

  • 回顾性研究,纳入 65 例未经治疗的肌肉骨骼肿瘤患者(恶性 47 例、良性 23 例),在 3T 下行包括体素内不相干运动扩散加权成像的 MRI 检查,由两名独立的肌肉骨骼放射科医生测量 IVIM 参数和单指数 ADC。

诊断标准与关键数值

  • 恶性肿瘤 D 值 923 ± 360 µm²/s vs 良性肿瘤 1668 ± 546 µm²/s,恶性肿瘤显著低于良性肿瘤(p < 0.001)。
  • 恶性肿瘤 ADC 值 965 ± 353 µm²/s vs 良性肿瘤 1689 ± 526 µm²/s,恶性肿瘤显著低于良性肿瘤(p < 0.001)。
  • 恶性肿瘤 f 值 9.6% vs 良性肿瘤 7.2%,恶性肿瘤显著高于良性肿瘤(p = 0.021)。
  • D* 值在良恶性肿瘤间无显著差异(p > 0.05)。
  • D、ADC 和 f 的 ROC 曲线下面积分别为 0.874、0.880 和 0.671。

临床应用与阅片要点

  • 在 3T IVIM DW 成像中,可测量 D 和 ADC 辅助鉴别良恶性肌肉骨骼肿瘤,取 cut-off 值 1200 µm²/s 时两者敏感度均为 92%。
  • D 和 ADC 的鉴别效能优于 f 和 D*,D 与 ADC 之间无显著差异,阅片时可结合 D 与 ADC 判断。
  • D* 在良恶性肿瘤间无显著差异,f 的曲线下面积仅 0.671,两者单独用于鉴别的价值有限。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the intravoxel incoherent motion (IVIM) diffusion-weighted (DW) MRI for differentiating between benign and malignant musculoskeletal tumours at 3 T.

METHODS: 65 patients with treatment-naïve musculoskeletal tumours (47 malignant and 23 benign lesions) who underwent 3 T MRI including IVIM DW imaging were included. IVIM-derived parameters included pure diffusion coefficient (D), perfusion related incoherent microcirculation (D*, pseudodiffusion coefficient), and perfusion fraction (f). IVIM parameters and mono-exponential apparent diffusion coefficient (ADC) were retrospectively measured by two independent musculoskeletal radiologists.

RESULTS: D and ADC values of malignant tumours (923 ± 360, 965 ± 353 µm2 s-1, respectively) were significantly lower than those of benign tumours (1668 ± 546, 1689 ± 526 µm2 s-1) (p < 0.001). F values of malignant tumours (9.6%) were significantly higher than those of benign tumours (7.2%) (p = 0.021), whereas D* values showed no significant difference (p > 0.05). The area under the receiver operating characteristic (ROC) curve of D, ADC and f were 0.874, 0.880 and 0.671, respectively. Using cut-off values of D and ADC of 1200 µm2 s-1, the sensitivity, specificity and accuracy were 92, 83, 89%, 92, 87 and 90%, respectively.

CONCLUSION: D and ADC may be more accurate and reliable for differentiation of malignant from benign musculoskeletal tumours than f and D* at 3 T IVIM DW imaging. Advances in knowledge: Among IVIM-derived parameters, D is more accurate and reliable in differentiating malignant from benign musculoskeletal tumours than f and D* at 3.0T IVIM DW imaging. There was no significant difference in the diagnostic performance of D and ADC.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Lim HK, Jee WH, Jung JY, et al. Intravoxel incoherent motion diffusion-weighted MR imaging for differentiation of benign and malignant musculoskeletal tumours at 3 T. Br J Radiol. 2017. PMID: 29144153. doi:10.1259/bjr.20170636

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。